Sleep And Wellness Medical Associates

CLIA Laboratory Citation Details

3
Total Citations
10
Total Deficiencyies
8
Unique D-Tags
CMS Certification Number 31D2037055
Address 31 E Darrah Lane, Lawrenceville, NJ, 08648
City Lawrenceville
State NJ
Zip Code08648
Phone609 587-9944
Lab DirectorMAHMOOD SIDDIQUE

Citation History (3 surveys)

Survey - March 30, 2023

Survey Type: Standard

Survey Event ID: 99DP11

Deficiency Tags: D5415 D5469 D5217 D5417 D5805

Summary:

Summary Statement of Deficiencies D5217 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(1) At least twice annually, the laboratory must verify the accuracy of any test or procedure it performs that is not included in subpart I of this part. This STANDARD is not met as evidenced by: Based on surveyor review of Proficiency Testing (PT) records, and interview with the Testing Personnel (TP), the laboratory failed to verify the accuracy and reliability of allergen testing twice a year from January 2022 to the date of survey. The finding includes: 1. The laboratory participated in American Proficiency Institute (API) PT Module Immunology/Immunohematology three events in 2022 that did not cover all 61 allergen analytes performed on the Optigen AP3600. 2. The TP confirmed on 3/30 /23 at 1:30 pm that the laboratory did not verify the accuracy of allergen testing twice a year. D5415 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(c) Reagents, solutions, culture media, control materials, calibration materials, and other supplies, as appropriate, must be labeled to indicate the following: (1) Identity and when significant, titer, strength or concentration. (2) Storage requirements. (3) Preparation and expiration dates. (4) Other pertinent information required for proper use. This STANDARD is not met as evidenced by: a) Based on surveyor observation of Quality Control (QC) material in use, review of the Liquid Assayed Multiqual Control Kit Manufacture Package Insert (MPI) and interview with the Testing Personnel (TP), the laboratory failed to put correct Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- expiration dates on QC material for Routine Chemistry tests at the time of survey. The findings include: 1. The expiration date of the QC material shortens once opened. 2. The laboratory had an open date of 3/29/23 and expiration date of 4/12/23 (fourteen days of stability) on QC material in use. 3. The MPI states Bilirubin, Cholesterol, Creatine Kinase, phosphorus and triglycerides have 7 days stability 4. The TP confirmed on 3/30/23 at 11:45 am the laboratory failed to put correct expiration dates on the control material. b) Based on surveyor observation of QC material in use, review of the Liquicxhek Immunoassay Plus Control Kit MPI and interview with the TP, the laboratory failed to put correct expiration dates on QC material for the routine chemistry and endocrinology tests at the time of survey. The findings include: 1. The expiration date of the QC material shortens once opened. 2. The laboratory had an open date of 3/29/23 and expiration date of 4/12/23 (fourteen days of stability) on QC material in use. 3. The MPI states Folate had 4 days stability. 4. The MPI states Estradoil has 8 days stability 5. The TP confirmed on 3/30/23 at 11:45 am the laboratory failed to put correct expiration dates on the control material. D5417 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(d) Reagents, solutions, culture media, control materials, calibration materials, and other supplies must not be used when they have exceeded their expiration date, have deteriorated, or are of substandard quality. This STANDARD is not met as evidenced by: Based on surveyor observation of Beckman Coulter CRP Latex calibrator Normal (N) set boxes and interview with the Testing Personnel (TP), the laboratory failed to discard expired Calibrator boxes from 2/1/23 to the date of survey. The finding include: 1. Two boxes of Beckman Coulter CRP Latex calibrator Normal (N) set lot #1066A expired 2/1/23 2. The TP confirmed on 3/30/23 at 12:30 pm that the laboratory failed to discard expired Calibrator. D5469 CONTROL PROCEDURES CFR(s): 493.1256(d)(10)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- Establish or verify the criteria for acceptability of all control materials. (i) When control materials providing quantitative results are used, statistical parameters (for example, mean and standard deviation) for each batch and lot number of control materials must be defined and available. (ii) The laboratory may use the stated value of a commercially assayed control material provided the stated value is for the methodology and instrumentation employed by the laboratory and is verified by the laboratory. (iii) Statistical parameters for unassayed control materials must be established over time by the laboratory through concurrent testing of control materials having previously determined statistical parameters. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on surveyor review of Quality Control (QC) records and interview with the Testing Personnel (TP), the laboratory failed to verify commercial QC material with each new lot and/or shipment of QC used for Allergy tests performed on Optigen -- 2 of 3 -- AP36000 analyzer on the date of survey. The finding includes: 1. There was no documented evidence that QC was verified before being put into use. 2. The TP confirmed on 3/30/23 at 11:20 am that the QC material was not verified before putting in use. D5805 TEST REPORT CFR(s): 493.1291(c) The test report must indicate the following: (c)(1) For positive patient identification, either the patient's name and identification number, or a unique patient identifier and identification number. (c)(2) The name and address of the laboratory location where the test was performed. (c)(3) The test report date. (c)(4) The test performed. (c)(5) Specimen source, when appropriate. (c)(6) The test result and, if applicable, the units of measurement or interpretation, or both. (c)(7) Any information regarding the condition and disposition of specimens that do not meet the laboratory's criteria for acceptability. This STANDARD is not met as evidenced by: Based on surveyor review of the Final Report (FR) and interview with the Testing Personnel (TP) the laboratory failed to ensure that the FR included all the required information on the date of survey. The finding include: 1. A review of ten FR revealed that the Es-triol did not have a normal patient range on the FR. 2. The TP confirmed on 3/30/23 at 10:45 am that FR did not have all the required information. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - August 31, 2021

Survey Type: Standard

Survey Event ID: HM0B11

Deficiency Tags: D5215 D6091 D5415

Summary:

Summary Statement of Deficiencies D5215 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(b)(2) The laboratory must verify the accuracy of any analyte, specialty or subspecialty assigned a proficiency testing score that does not reflect laboratory test performance (that is, when the proficiency testing program does not obtain the agreement required for scoring as specified in subpart I of this part, or the laboratory receives a zero score for nonparticipation, or late return or results). This STANDARD is not met as evidenced by: Based on surveyor review of the Proficiency Testing (PT) records and interview with the Laboratory Director (LD), the laboratory failed to verify the accuracy of chemistry and endocrinology test results obtained from the American Proficiency Institute (API) from January 2020 to the date of survey. The findings include: 1. The laboratory received a score of 100 but results were not graded. 2. There was no documented evidence the laboratory verified: a) Estriol events 1,2,3 2020 and 1, 2021. b) Apolipoprotien A1 event 2, 2020. 3. The LD confirmed on 8-31-21 at 2:10 pm accuracy of the PT results were not verified D5415 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(c) Reagents, solutions, culture media, control materials, calibration materials, and other supplies, as appropriate, must be labeled to indicate the following: (1) Identity and when significant, titer, strength or concentration. (2) Storage requirements. (3) Preparation and expiration dates. (4) Other pertinent information required for proper use. This STANDARD is not met as evidenced by: Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- Based on surveyor observation of the Quality Control (QC) material and interview with the Laboratory Director (LD), the laboratory failed to put open and expiration dates on Routine Chemistry and Endocrinology QC material in use at the time of survey. The findings include. 1. The expiration date of control material shortens once opened. 2. The laboratory did not put open and expiration dates on: a. Liquichek Immunoassay Plus Control (Lot 85261, 62) b. Lyphochek Liquid Assayed Multiqual Control (Lot 45831, 32 & 33) c. Quantimetrix Vitamin D (Lot 29151 & 52) d. Sex Hormone Binding Globulin (SHBG) Access QC 1 and QC 2 (Lot 9M0076) e. Liquichek Specialty Immunoassy Control Lot (64931 & 33) f. Liquicheck Elevated CRP control lot (35463 & 65461) 3. The LD confirmed on 8/31/21 at 2:30 pm the laboratory failed to put open and expiration dates on the control material. Note: This deficiency was previously cited. The POC state "all current reagents, calibrators, and Quality Controls are labeled with the following: date received, opened and initials" D6091 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(4)(iii) The laboratory director must ensure all proficiency testing reports received are reviewed by the appropriate staff to evaluate the laboratory's performance and to identify any problems that require

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - June 21, 2018

Survey Type: Standard

Survey Event ID: F0T711

Deficiency Tags: D5401 D5415

Summary:

Summary Statement of Deficiencies D5401 PROCEDURE MANUAL CFR(s): 493.1251(a) A written procedures manual for all tests, assays, and examinations performed by the laboratory must be available to, and followed by, laboratory personnel. Textbooks may supplement but not replace the laboratory's written procedures for testing or examining specimens. This STANDARD is not met as evidenced by: Based on surveyor review of the Procedure Manual (PM), Quality Control (QC) records and interview with the Technical Consultant (TC), the laboratory failed to follow the QC new lot verification procedure to ensure QC was within the acceptable ranges before it was put into use for analytes performed on the Beckman Coulter AU 480 and Access 2 analyzer from 5/17/16 to the date of the survey. The findings include: 1. The PM stated that QC new lot verification will be performed three times before using. 2. A review of the QC records revealed Liquid Assayed Multiqual Control (Lot 45781, 82, 83), Liquichek C-Reactive Protein (CRP) Control (Lot 35421 & 23) and Sex Hormone Binding Globulin (SHBG) Access QC 1 and QC 2 (Lot 7M0054) were not verified before use. 3. Quantimetrix Vitamin D Control (Lot 29131 & 32) was not run three times prior to using. 4. The TC confirmed on 6/21/18 at 10:30 am that the laboratory did not follow the PM. D5415 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(c) Reagents, solutions, culture media, control materials, calibration materials, and other supplies, as appropriate, must be labeled to indicate the following: (1) Identity and when significant, titer, strength or concentration. (2) Storage requirements. (3) Preparation and expiration dates. (4) Other pertinent information required for proper use. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- This STANDARD is not met as evidenced by: Based on surveyor observation of the Quality Control (QC) material and interview with the Technical Consultant (TC), the laboratory failed to put open and expiration dates on Routine Chemistry and Endocrinology QC material in use at the time of survey. The findings include. 1. The expiration date of control material shortens once opened. 2. The laboratory did not put open and expiration dates on: a. Liquichek Immunoassay Plus Control (Lot 40951, 52 & 53) b. Lyphochek Liquid Assayed Multiqual Control (Lot 45781, 82 & 83) c. Quantimetrix Vitamin D (Lot 29131 & 32) d. Sex Hormone Binding Globulin (SHBG) Access QC 1 and QC 2 (Lot 7M0054) e. Liquichek C-Reactive Protein (CRP) Lot (35421 & 23) 3. The TC confirmed on 6/21 /18 at 11:30 am the laboratory failed to put open and expiration dates on the control material. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access