Smgmg

CLIA Laboratory Citation Details

2
Total Citations
13
Total Deficiencyies
12
Unique D-Tags
CMS Certification Number 31D1080172
Address 1011 Clifton Avenue, Clifton, NJ, 07013
City Clifton
State NJ
Zip Code07013
Phone862 591-2002
Lab DirectorMICHAEL MAROULES

Citation History (2 surveys)

Survey - June 6, 2023

Survey Type: Standard

Survey Event ID: 5PW411

Deficiency Tags: D5601 D6021 D3033 D5403

Summary:

Summary Statement of Deficiencies D3033 RETENTION REQUIREMENTS CFR(s): 493.1105(a)(3)(i) In addition, the laboratory must retain records of test system performance specifications that the laboratory establishes or verifies under 493.1253 for the period of time the laboratory uses the test system but no less than 2 years. This STANDARD is not met as evidenced by: Based on the lack of Performance Specifications (PS) and interview with the Testing Personnel (TP), the laboratory failed to retain PS records for the Horiba ABX Micros analyzer used to perform Hematology Testing from 11/14/2019 to the date of survey. The findings include: 1) There were no linearity records. 2) There was no source for normal Patient range. 3) The TP confirmed via email on 6/12/23 at 2:15 pm that all PS records were not retained. D5403 PROCEDURE MANUAL CFR(s): 493.1251(b) The procedure manual must include the following when applicable to the test procedure: (1) Requirements for patient preparation; specimen collection, labeling, storage, preservation, transportation, processing, and referral; and criteria for specimen acceptability and rejection as described in 493.1242. (2) Microscopic examination, including the detection of inadequately prepared slides. (3) Step-by-step performance of the procedure, including test calculations and interpretation of results. (4) Preparation of slides, solutions, calibrators, controls, reagents, stains, and other materials used in testing. (5) Calibration and calibration verification procedures. (6) The reportable range for test results for the test system as established or verified in 493.1253. (7) Control procedures. (8)

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - November 14, 2019

Survey Type: Standard

Survey Event ID: 2QI811

Deficiency Tags: D5217 D5415 D5433 D5601 D5787 D5803 D2000 D6074 D6094

Summary:

Summary Statement of Deficiencies D2000 ENROLLMENT AND TESTING OF SAMPLES CFR(s): 493.801 Each laboratory must enroll in a proficiency testing (PT) program that meets the criteria in subpart I of this part and is approved by HHS. The laboratory must enroll in an approved program or programs for each of the specialties and subspecialties for which it seeks certification. The laboratory must test the samples in the same manner as patients' specimens. For laboratories subject to 42 CFR part 493 published on March 14, 1990 (55 FR 9538) prior to September 1, 1992, the rules of this subpart are effective on September 1, 1992. For all other laboratories, the rules of this subpart are effective January 1, 1994. This CONDITION is not met as evidenced by: Based on the lack of Proficiency Testing (PT) records and interview with the Testing Personnel (TP), the laboratory failed to enroll in an approved PT program for Manual Differential (MD) tests from 11/29/17 to the date of survey. The TP #1 listed on CMS form 209 confirmed on 11/14/19 at 1:00 pm the laboratory was not enrolled in PT testing for MD. D5217 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(1) At least twice annually, the laboratory must verify the accuracy of any test or procedure it performs that is not included in subpart I of this part. This STANDARD is not met as evidenced by: Based on surveyor review of the Proficiency Testing (PT) records and interview with the Testing Personnel (TP), the laboratory failed to verify the accuracy and reliability of Bone Marrow smear tests twice a year from 11/29/17 to the date of survey. The TP Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 4 -- #1 listed on CMS form 209 confirmed on 11/14/19 at 2:00 pm that the laboratory did not verify the accuracy of above mentioned tests. D5415 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(c) Reagents, solutions, culture media, control materials, calibration materials, and other supplies, as appropriate, must be labeled to indicate the following: (1) Identity and when significant, titer, strength or concentration. (2) Storage requirements. (3) Preparation and expiration dates. (4) Other pertinent information required for proper use. This STANDARD is not met as evidenced by: Based on surveyor review of Manufactures Package Insert, observation of the Quality Control material, and interview with the Testing Personnel (TP), the laboratory failed to put a new expiration date on Hematology Control material used on the Horiba ABX Micros 60 on the date of the survey. The TP #1 listed on CMS form 209 confirmed on 11/14/19 at 1:10 pm the laboratory failed to put a new expiration date on the control material. D5433 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(b)(1) For equipment, instruments, or test systems developed in-house, commercially available and modified by the laboratory, or maintenance and function check protocols are not provided by the manufacturer, the laboratory must establish a maintenance protocol that ensures equipment, instrument, and test system performance that is necessary for accurate and reliable test results and test result reporting. The laboratory must perform and document the maintenance activities specified in paragraph (b)(1)(i) of this section. This STANDARD is not met as evidenced by: Based on surveyor review of the laboratory records, procedure manual and interview with the Testing Personnel (TP), the laboratory failed to establish a maintenance protocol for the Microscope when protocols were not provided by the manufacturer from 11/29/17 to the date of the survey. The TP #1 listed on CMS form 209 confirmed on 11/14/19 at 1:30 pm that the laboratory did not establish a maintenance protocol. D5601 HISTOPATHOLOGY CFR(s): 493.1273(a)(f) (a) As specified in 493.1256(e)(3), fluorescent and immunohistochemical stains must be checked for positive and negative reactivity each time of use. For all other differential or special stains, a control slide of known reactivity must be stained with each patient slide or group of patient slides. Reactions of the control slide with each special stain must be documented. (f) The laboratory must document all control procedures performed, as specified in this section. This STANDARD is not met as evidenced by: -- 2 of 4 -- Based on lack of Quality Control (QC) records and interview with the Testing Personnel (TP), the laboratory failed to document the reaction of a control slide for the iron stain used for Histopathology tests from 11/29/17 to the date of the survey. The TP #1 listed on CMS form 209 confirmed on 11/14/19 at 1:25 pm that the laboratory did not document the reaction of a control slide. D5787 TEST RECORDS CFR(s): 493.1283(a) The laboratory must maintain an information or record system that includes the following: (a)(1) The positive identification of the specimen. (a)(2) The date and time of specimen receipt into the laboratory. (a)(3) The condition and disposition of specimens that do not meet the laboratory's criteria for specimen acceptability. (a)(4) The records and dates of all specimen testing, including the identity of the personnel who performed the test(s). This STANDARD is not met as evidenced by: Based on lack of an Accession Log (AL) and interview with the Testing Personnel (TP), the laboratory failed to maintain an Accession Log (AL) for Hematology peripheral smears and Bone Marrow smear tests from 11/29/17 to the date of survey. The TP #1 listed on CMS form 209 confirmed on 11/14/19 at 2:15 pm that the laboratory did not maintain an AL for the above mentioned tests. D5803 TEST REPORT CFR(s): 493.1291(b) Test report information maintained as part of the patient's chart or medical record must be readily available to the laboratory and to CMS or a CMS agent upon request. This STANDARD is not met as evidenced by: Based on the surveyor review of the Test Reports (TR) and interview with the Testing Personnel (TP), the laboratory failed to have a TR for Manual Differential (MD) tests from 11/17/17 to the date of the survey. The TP #1 listed on CMS form 209 confirmed on 11/14/19 at 2:10 pm that MD tests did not have a TR. D6074 TESTING PERSONNEL RESPONSIBILITIES CFR(s): 493.1425(b)(5) Each individual performing moderate complexity testing must be capable of identifying problems that may adversely affect test performance or reporting of test results and either must correct the problems or immediately notify the technical consultant, clinical consultant or director. This STANDARD is not met as evidenced by: Based on surveyor review of the Quality Control (QC) records and interview with the Testing Personnel (TP), the TP failed to identify problems that may affect test performance by not reviewing and evaluating trends and/or shifts for tests performed on the Horiba ABX Micros 60 analyzer from 11/29/17 to the date of the survey. The TP #1 listed on CMS form 209 confirmed on 11/14/19 at 1:45 pm that trends and shifts were not reviewed. -- 3 of 4 -- D6094 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(5) The laboratory director must ensure that the quality assessment programs are established and maintained to assure the quality of laboratory services provided and to identify failures in quality as they occur. This STANDARD is not met as evidenced by: Based on surveyor review of the laboratory Procedure Manual and interview with the Testing Personnel (TP), the Laboratory Director failed to ensure a Quality Assurance (QA) program was established to assure quality of laboratory services provided from 11/29/17 to the date of the survey. The TP #1 listed on CMS form 209 confirmed on 11/14/19 at 1:45 pm that a QA program was not established. -- 4 of 4 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access