Sound Medical Care Pc

CLIA Laboratory Citation Details

2
Total Citations
17
Total Deficiencyies
8
Unique D-Tags
CMS Certification Number 33D0160533
Address 516 Montauk Highway Ste 1, East Moriches, NY, 11940
City East Moriches
State NY
Zip Code11940
Phone(631) 874-2900

Citation History (2 surveys)

Survey - December 23, 2021

Survey Type: Special

Survey Event ID: 955S11

Deficiency Tags: D2016 D2028 D6000 D2028 D6000 D6016 D6016

Summary:

Summary Statement of Deficiencies D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on proficiency testing (PT) desk review of the Center for Medicare and Medicaid Services (CMS) PT data reports and PT records from the American Academy of Family Physicians (AAFP) PT program, the laboratory failed to participate successfully in proficiency testing for the sub-specialty Bacteriology /Throat cultures. The following scores were assigned: 2021 second event = 0% [non- participation] 2021 third event = 0% [non-participation] This is considered unsuccessful PT performance. Refer to D2028. D2028 BACTERIOLOGY Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- CFR(s): 493.823(e) Failure to achieve an overall testing event score of satisfactory performance for two consecutive testing events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on PT desk review of the CMS PT data reports and PT records from the AAFP PT program, the laboratory failed to participate successfully in proficiency testing for the sub-specialty Bacteriology/Throat cultures. The following scores were assigned: 2021 second event = 0% [non-participation] 2021 third event = 0% [non-participation] This is considered unsuccessful PT performance D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on PT desk review of the PT CMS data reports and AAFP PT reports, the laboratory director failed to fulfill the laboratory director's responsibilities and ensure that the laboratory achieved a satisfactory performance and successfully participate in a PT program, for the sub-specialty Bacteriology/Throat Culture. Refer to D6016. D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(i) Ensure that the proficiency testing samples are tested as required under Subpart H of this part; This STANDARD is not met as evidenced by: Based on PT desk review of the PT CMS data reports and AAFP PT reports, the laboratory director failed to fulfill the laboratory director's responsibilities and ensure that the laboratory achieved a satisfactory performance and successfully participate in a PT program, for the sub-specialty Bacteriology/Throat Culture. The following scores were assigned: 2021 second event = 0% [non-participation] 2021 third event = 0% [non-participation] This is considered unsuccessful PT performance -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - March 13, 2019

Survey Type: Standard

Survey Event ID: WI8P11

Deficiency Tags: D1001 D5471 D5477 D6000 D6020 D1001 D5471 D5477 D6000 D6020

Summary:

Summary Statement of Deficiencies D1001 CERTIFICATE OF WAIVER TESTS CFR(s): 493.15(e) Laboratories eligible for a certificate of waiver must-- (1) Follow manufacturers' instructions for performing the test; and (2) Meet the requirements in subpart B, Certificate of Waiver, of this part. This STANDARD is not met as evidenced by: Based on surveyor's review of the manufacturer's packet insert for Siemens Multistix and interview with the laboratory supervisor and the testing person, the laboratory failed to follow the manufacturer's requirements for performing external positive and negative controls with each new vial opened for the urine Multistix. FINDINGS: 1. The laboratory is using Siemens Multistix. The packet insert for the urine Multistix requires that external controls be performed with each new Vial of Multistix opened. 2. On March 13, 2019 at approximately 11:00 AM the laboratory supervisor and the testing person confirmed surveyor's findings that documentation for the required external control testing was not available for the current Multistix vial in use, lot # 712008, expiration date 5/31/19. 3. Approximately 50 patients specimens were tested and reported for urinalysis using the above vial Multistix. D5471 CONTROL PROCEDURES CFR(s): 493.1256(e)(1)(g) (e) For reagent, media, and supply checks, the laboratory must do the following: (e)(i) Check each batch (prepared in-house), lot number (commercially prepared) and shipment of reagents, disks, stains, antisera, (except those specifically referenced in 493.1261 (a)(3)) and identification systems (systems using two or more substrates or two or more reagents, or a combination) when prepared or opened for positive and negative reactivity, as well as graded reactivity, if applicable. (g) The laboratory must document all control procedures performed. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- This STANDARD is not met as evidenced by: Based on surveyor's review of the bacteriology Quality Control (QC) documentation and an interview with the laboratory supervisor and the testing person, the laboratory failed to check each new batch, lot number and shipment of 0.04 bacitracin disc for positive and negative reactivity in calendar year 2017 through January 24, 2019. FINDINGS: 1. On March 13, 2019 at approximately 11:00 AM the laboratory supervisor and the testing person confirmed surveyor's findings that the laboratory failed to check each new batch, lot number and shipment of the bacitracin disc for positive and negative reactivity from February 2017 through January 24, 2019. 2. The laboratory failed to record the lot number/expiration date for the shipment of bacitracin disc received in the lab from February 2017 through January 24, 2019. 3. Approximately 700 patients specimens were tested and reported for throat culture during this time period. D5477 CONTROL PROCEDURES CFR(s): 493.1256(e)(4)(g) (e) For reagent, media, and supply checks, the laboratory must do the following: (e) (4) Before, or concurrent with the initial use-- (e)(4)(i) Check each batch of media for sterility if sterility is required for testing; (e)(4)(ii) Check each batch of media for its ability to support growth and, as appropriate, select or inhibit specific organisms or produce a biochemical response; and (e)(4)(iii) Document the physical characteristics of the media when compromised and report any deterioration in the media to the manufacturer. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on a surveyor's review of records and confirmed in an interview with the laboratory supervisor and the testing person at the time of this survey, the laboratory failed to perform bacteriology QC as required from February 2017 through January 24, 2019. The laboratory failed to: 1. Perform and document the sterility for the Selective Strep Agar (SSA) Media; 2. Document the physical characteristics of the SSA Media for any deterioration; 3. Check each new batch, lot number and shipment of SSA Media for positive and negative reactivity. Approximately 700 patient specimens were tested and reported for throat culture during the above time period. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on surveyor findings and interview with the laboratory supervisor and the testing person, the laboratory director failed to provide overall management of the laboratory. The laboratory director failed to ensure that the laboratory maintained the laboratory's QC program for bacteriology. Refer to D6020 D6020 LABORATORY DIRECTOR RESPONSIBILITIES -- 2 of 3 -- CFR(s): 493.1407(e)(5) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(5) Ensure that the quality control program is established and maintained to assure the quality of laboratory services provided. This STANDARD is not met as evidenced by: Based on the surveyor's review of Quality Control (QC) records and confirmed, during this onsite survey with the laboratory supervisor and the testing person, the laboratory director failed to ensure that the QC program for bacteriology testing was maintained to assure quality of laboratory services. Refer to: D1001, D5471, D5477 -- 3 of 3 --