Southwest Medical Associates-S Eastern

CLIA Laboratory Citation Details

1
Total Citation
5
Total Deficiencyies
5
Unique D-Tags
CMS Certification Number 29D0539151
Address 4475 S Eastern Ave, Las Vegas, NV, 89119
City Las Vegas
State NV
Zip Code89119
Phone702 669-5843
Lab DirectorYOUNG CHO

Citation History (1 survey)

Survey - December 17, 2025

Survey Type: null

Survey Event ID: 6RPT11

Deficiency Tags: D2016 D6000 D0000 D2096 D6016

Summary:

Summary Statement of Deficiencies D0000 This Statement of Deficiencies was generated as a result of the CLIA proficiency testing desk review, conducted off-site for your laboratory on December 17, 2025. The findings and conclusions of any investigation by the Nevada Health Authority Division of Healthcare Purchasing and Compliance shall not be construed as prohibiting any criminal or civil investigations, actions or other claims for relief that may be available to any party under applicable federal, state, or local laws. D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on the findings herein, the Condition: Successful Participation (in a proficiency testing program) was not met. A review of the federal database CASPER Report Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- 0155D and the College of American Pathologists (CAP) proficiency testing (PT) evaluation forms on December 17, 2025 found that the laboratory failed to successfully participate in a proficiency testing program. Findings include: The laboratory failed to maintain successful participation with the CAP PT program shown by the unsuccessful performance for B-Type Natriuretic (BNP) in the second PT event of 2025 and for the third PT event of 2025. Refer to D2096. D2096 ROUTINE CHEMISTRY CFR(s): 493.841(f) (f) Failure to achieve satisfactory performance for the same analyte or test in two consecutive testing events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on a review of the federal database CASPER Report 0155D and the College of American Pathologists (CAP) proficiency testing (PT) evaluation forms on December 17, 2025, the laboratory failed to ensure successful participation in a proficiency testing program. Findings include: 1. The laboratory director failed to ensure successful participation with the CAP PT program shown by the unsuccessful performance for BNP in the second PT event of 2025 and third PT event 2025. 2. The CASPER Report 0155D reported a score of 40% for the second PT event of 2025 and 0% for the third PT event of 2025. 3. The CAP PT evaluation submitted by the laboratory for the second PT event of 2025 reported a score of 40%. There was no CAP PT evaluation for the third PT Event of 2025 submitted for review. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on the findings herein, the Condition: Laboratories Performing Moderate Complexity Testing; Laboratory Director was not met. A review of the federal database CASPER Report 0155D and the College of American Pathologists (CAP) proficiency testing (PT) evaluation forms on December 17, 2025 found that the laboratory director failed to ensure successful participation in a proficiency testing program. Findings include: The laboratory director failed to ensure successful participation with the CAP PT program shown by the unsuccessful performance for B- Type Natriuretic Peptide (BNP) in the second PT event of 2025 and for the third PT event of 2025. Refer to D6016. D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) (e)(4)(i) The proficiency testing samples are tested as required under Subpart H of this part; -- 2 of 3 -- This STANDARD is not met as evidenced by: Based on a review of the federal database CASPER Report 0155D and the College of American Pathologists (CAP) proficiency testing (PT) evaluation forms on December 17, 2025, the laboratory director failed to ensure successful participation in a proficiency testing program. Findings include: 1. The laboratory director failed to ensure successful participation with the CAP PT program shown by the unsuccessful performance for BNP in the second PT event of 2025 and third PT event 2025. 2. The CASPER Report 0155D reported a score of 40% for the second PT event of 2025 and 0% for the third PT event of 2025. 3. The CAP PT evaluation submitted by the laboratory for the second PT event of 2025 reported a score of 40%. There was no CAP PT evaluation for the third PT Event of 2025 submitted for review. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access