Sperm Bank Of California

CLIA Laboratory Citation Details

1
Total Citation
1
Total Deficiency
1
Unique D-Tag
CMS Certification Number 05D0602416
Address 2115 Milvia St, 2nd Flr, Berkeley, CA
City Berkeley
State CA

Citation History (1 survey)

Survey - October 1, 2025

Survey Type: Standard

Survey Event ID: 7XQT11

Deficiency Tags: D5217

Summary:

Summary Statement of Deficiencies D5217 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(1) At least twice annually, the laboratory must verify the accuracy of any test or procedure it performs that is not included in subpart I of this part. This STANDARD is not met as evidenced by: Based on observation of Makler Chambers, review of laboratory test records for Semen Analysis and 2024-2025 proficiency testing reports from AAB/MLE (American Association of Bioanalysts/Medical Laboratory Evaluation), and interview with laboratory personnel, it was determined that the laboratory failed to verify the accuracy of testing for Sperm Count and Sperm Motility. Findings included: a. The laboratory performed Semen Analysis using the Makler Chamber to manually count, calculate, and report results for Sperm Count and Sperm Motility. b. The laboratory participated in AAB/MLE's proficiency testing program titled, "Embryology, Andrology & Fetal", as the means to fulfill the requirement to at least twice annually verify the accuracy of testing. c. Sperm Count 1. AAB/MLE reported unsatisfactory scores of 50% due to the laboratory's 1 unacceptable result (*) out of 2, for Sperm Count, as follows: Event PT Lab Mean/ Sample result Intended Results ------------------------------------------------------------- 2, 2024 7 22 * 39.7 1, 2025 1 20* 38.7 d. Sperm Motility 1. AAB/MLE reported the unsatisfactory score of 0% due to the laboratory's 2 unacceptable results (*) out of 2, for Sperm Motility, as follows: Event PT Lab Mean/ Sample result Intended Results ------------------------------------------------------------- 1, 2025 1 37 * 21.5 2 27* 10.8 e. The laboratory had no records for alternate methods of verifying test accuracy for Sperm Count and Sperm Motility. f. The Laboratory Executive Director /Administrator affirmed (10/01/25 at 12:30 PM) the aforementioned findings. g. And thus, the reliability and quality of results reported could not be assured during this Survey for Sperm Counts and Sperm Motility. The laboratory affirmed (by Email, 10 /03/25 at 11:31 AM) reporting 585 Semen Analyses during the timeframe 5/06/24 to 9 Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- /13/25. Semen Analysis laboratory reports selected for review are, as follows: Date Acc # -------------------------------- 5/06/24 95620 6/05/25 95824 9/11/25 95872 . -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access