Ssm Health Dean Medical Group-South Madison Campus

CLIA Laboratory Citation Details

2
Total Citations
6
Total Deficiencyies
3
Unique D-Tags
CMS Certification Number 52D0393534
Address 1211 Fish Hatchery Rd, Madison, WI, 53715
City Madison
State WI
Zip Code53715
Phone608 283-7014
Lab DirectorMOLLY GURNEY

Citation History (2 surveys)

Survey - April 11, 2023

Survey Type: Standard

Survey Event ID: G3NQ11

Deficiency Tags: D5413 D5439 D5413 D5439

Summary:

Summary Statement of Deficiencies D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: Based on surveyor observation of the chemistry freezer, review of chemistry freezer temperature log, and interview with the general supervisor, the laboratory did not define an acceptable temperature range that was consistent with the manufacturer's acceptable range for the Maine Standards calibration verification material stored in Freezer 1 and two hundred eighty-two days of two hundred eighty-three days were out of acceptable range in 2022 and 2023 Findings include: 1. Observation of Maine Standards Validate GC3, GC4, and GC1 calibration verification material in Freezer 1 on April 11, 2023, at 1:50 PM showed the manufacturer required storage at -10 to -25 Celsius (C). 3. Review of the temperature logs for 2022 and 2023 showed the defined acceptable temperature range for Freezer 1 was less than or equal to 20 C. Two hundred eighty-two days of two hundred eighty-three days showed recorded temperatures were colder than -25 C. 4. Interview with the general supervisor on April 11, 2023, at 1:54 PM confirmed the laboratory's acceptable range for Freezer 1 was not consistent with the manufacturer's acceptable range for the Maine Standards calibration material. D5439 CALIBRATION AND CALIBRATION VERIFICATION Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- CFR(s): 493.1255(b) Unless otherwise specified in this subpart, for each applicable test system the laboratory must do the following: Perform and document calibration verification procedure - (b)(1) Following the manufacturer's calibration verification instructions; (b)(2) Using the criteria verified or established by the laboratory under 493.1253(b)(3) -- (b)(2)(i) Including the number, type, and concentration of the materials, as well as acceptable limits for calibration verification; and (b)(2)(ii) Including at least a minimal (or zero) value, a mid-point value, and a maximum value near the upper limit of the range to verify the laboratory's reportable range of test results for the test system; and (b)(3) At least once every 6 months and whenever any of the following occur: (b)(3)(i) A complete change of reagents for a procedure is introduced, unless the laboratory can demonstrate that changing reagent lot numbers does not affect the range used to report patient test results, and control values are not adversely affected by reagent lot number changes. (b)(3)(ii) There is major preventive maintenance or replacement of critical parts that may influence test performance. (b)(3)(iii) Control materials reflect an unusual trend or shift, or are outside of the laboratory's acceptable limits, and other means of assessing and correcting unacceptable control values fail to identify and correct the problem. (b)(3)(iv) The laboratory's established schedule for verifying the reportable range for patient test results requires more frequent calibration verification. This STANDARD is not met as evidenced by: Based on surveyor review of calibration verification records, patient testing reports and interview with a technical specialist, staff A, the laboratory did not perform calibration verification every six months on the Abbott Alinity chemistry analyzer in 2022. Finding include: 1. Review of calibration verification records showed calibration verification performed on the Abbott Alinity chemistry analyzer on January 24, 2022, and August 3, 2022. Further review showed no evidence of additional calibration verification performed on the analyzer in 2022 when calibration verification was due on July 24, 2022. 2. Review of patient testing reports showed two hundred and nine patient tests were performed between July 25, 2022, and August 3, 2022. 3. Interview with the staff A on April 11, 2023, at 1:53 PM confirmed the laboratory did not perform calibration verification every six months on the Abbott Alinity chemistry analyzer in 2022. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - April 23, 2019

Survey Type: Standard

Survey Event ID: 06ZQ11

Deficiency Tags: D5217 D5217

Summary:

Summary Statement of Deficiencies D5217 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(1) At least twice annually, the laboratory must verify the accuracy of any test or procedure it performs that is not included in subpart I of this part. This STANDARD is not met as evidenced by: Based on surveyor review of laboratory dermatopathology records and interview with the histopathology laboratory specialist, the laboratory has not evaluated the accuracy of Mohs testing twice annually in 2018. Findings include: 1. Review of laboratory dermatopathology records from 2018 show no evidence of twice annual accuracy evaluation for Mohs test results. 2. Interview with the histopathology laboratory specialist on April 23, 2019 at 2:15 PM confirmed twice annual accuracy verification of Mohs test results had not been performed in 2018. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access