St Dominic's Gynecologic Oncology

CLIA Laboratory Citation Details

2
Total Citations
5
Total Deficiencyies
5
Unique D-Tags
CMS Certification Number 25D1022336
Address 971 Lakeland Dr Ste 750, Jackson, MS, 39216
City Jackson
State MS
Zip Code39216
Phone601 200-4970
Lab DirectorD SEAGO

Citation History (2 surveys)

Survey - November 29, 2022

Survey Type: Standard

Survey Event ID: JZUP11

Deficiency Tags: D5401 D5403 D6049

Summary:

Summary Statement of Deficiencies D5401 PROCEDURE MANUAL CFR(s): 493.1251(a) A written procedures manual for all tests, assays, and examinations performed by the laboratory must be available to, and followed by, laboratory personnel. Textbooks may supplement but not replace the laboratory's written procedures for testing or examining specimens. This STANDARD is not met as evidenced by: Based on review of installation procedures for the Sysmex XP-300, interview with testing personnel (TP) #1 on 11/29/2022 at 3:30 p.m., and lack of a written procedure manual, the laboratory failed to establish a written procedure manual for performing CBC (Complete Blood Count) testing with the Sysmex XP-300 Hematology analyzer, in use for patient testing from 08/12/2021 through 11/29/2022. Findings include: 1. The laboratory has an annual volume of 944 patient samples for CBC. 2. There was no procedure manual available for review on 11/29/2022 for performing patient CBC's on the Sysmex XP-300 Hematology analyzer. 3. The LD/TC confirmed in an interview on 11/29/2022 at 3:30 p.m. that there was no written procedure for performing CBC's, approved and signed by the laboratory director. D5403 PROCEDURE MANUAL CFR(s): 493.1251(b) The procedure manual must include the following when applicable to the test procedure: (1) Requirements for patient preparation; specimen collection, labeling, storage, preservation, transportation, processing, and referral; and criteria for specimen acceptability and rejection as described in 493.1242. (2) Microscopic examination, including the detection of inadequately prepared slides. (3) Step-by-step performance of the procedure, including test calculations and interpretation of results. (4) Preparation of slides, solutions, calibrators, controls, reagents, stains, and other Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- materials used in testing. (5) Calibration and calibration verification procedures. (6) The reportable range for test results for the test system as established or verified in 493.1253. (7) Control procedures. (8)

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - December 17, 2019

Survey Type: Special

Survey Event ID: I7VM11

Deficiency Tags: D2130 D2016

Summary:

Summary Statement of Deficiencies D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on surveyor desk review of the laboratory proficiency testing (PT) records (graded copies from the proficiency testing provider and the Centers for Medicare and Medicaid Services data system) on 12/17/2019, the laboratory has not successfully participated in proficiency testing for WHITE BLOOD CELL (WBC) DIFFERENTIAL. Findings include: Our records indicate the following proficiency testing scores for your laboratory for WHITE BLOOD CELL (WBC) DIFFERENTIAL: PROFICIENCY TESTING PROVIDER: American Academy of Family Physicians WHITE BLOOD CELL (WBC) DIFFERENTIAL: Year 2019 2nd Event 0% Year 2019 3rd Event 0% Scores less than 80% for this analyte or parameter Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- indicate failure for unsatisfactory performance. A failure of the analyte or parameter for two consecutive or two out of three testing events is scored as initial unsuccessful performance. D2130 HEMATOLOGY CFR(s): 493.851(f) Failure to achieve satisfactory performance for the same analyte in two consecutive events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on surveyor desk review of the laboratory proficiency testing (PT) records (graded copies from the proficiency testing provider and the Centers for Medicare and Medicaid Services data system) on 12/17/2019, the laboratory has not successfully participated in proficiency testing for WHITE BLOOD CELL (WBC) DIFFERENTIAL. Findings include: Our records indicate the following proficiency testing scores for your laboratory for WHITE BLOOD CELL (WBC) DIFFERENTIAL: PROFICIENCY TESTING PROVIDER: American Academy of Family Physicians WHITE BLOOD CELL (WBC) DIFFERENTIAL: Year 2019 2nd Event 0% Year 2019 3rd Event 0% Scores less than 80% for this analyte or parameter indicate failure for unsatisfactory performance. A failure of the analyte or parameter for two consecutive or two out of three testing events is scored as initial unsuccessful performance. -- 2 of 2 --