Stevens County Hospital

CLIA Laboratory Citation Details

1
Total Citation
6
Total Deficiencyies
6
Unique D-Tags
CMS Certification Number 17D0047372
Address 1006 S Jackson St, Hugoton, KS, 67951
City Hugoton
State KS
Zip Code67951
Phone(620) 544-8511

Citation History (1 survey)

Survey - May 19, 2021

Survey Type: Standard

Survey Event ID: JMZN11

Deficiency Tags: D6042 D6108 D6117 D6118 D6119 D6123

Summary:

Summary Statement of Deficiencies D6042 TECHNICAL CONSULTANT RESPONSIBILITIES CFR(s): 493.1413(b)(4) (b) The technical consultant is responsible for-- (b)(4) Establishing a quality control program appropriate for the testing performed and establishing the parameters for acceptable levels of analytic performance and ensuring that these levels are maintained throughout the entire testing process from the initial receipt of the specimen, through sample analysis and reporting of test results; This STANDARD is not met as evidenced by: Review of quality control and patient test records from 4/1/2019 to 4/30/2021 and interview revealed the Technical Consultant (TC) failed to ensure acceptable levels of analytic performance were maintained for the OPTI-CCA-TS2. Findings: 1. Examination of the OPTI-CCA-TS2 quality control and patient test records revealed no review documentation by the TC from 4/1/2019 to 4/30/2021. 2. Interview with Testing Personell #4 on 5/19/21 at 10:55 a.m. confirmed, the TC failed to ensure acceptable levels of analytic performance were maintained for the OPTI-CCA-TS2. D6108 LABORATORY TECHNICAL SUPERVISOR CFR(s): 493.1447 The laboratory must have a technical supervisor who meets the qualification requirements of 493.1449 of this subpart and provides technical supervision in accordance with 493.1451 of this subpart. This CONDITION is not met as evidenced by: The Technical Supervisor (TS) of immunohematology failed to provide supervision in accordance with 493.1451. See D6117, D6118, D6119 and D6123. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- D6117 TECHNICAL SUPERVISOR RESPONSIBILITIES CFR(s): 493.1451(b)(4) The technical supervisor is responsible for establishing a quality control program appropriate for the testing performed and establishing the parameters for acceptable levels of analytic performance and ensuring that these levels are maintained throughout the entire testing process from the initial receipt of the specimen, through sample analysis and reporting of test results. This STANDARD is not met as evidenced by: Based on review of 4/2/19 to 5/19/21 patient testing logs and interview, the TS for immunohematology failed to ensure analytical performance was maintained at acceptable levels. Findings: 1. No documentation of review by the TS for immunohematology of patient testing logs with test reactions and interpretation were available for 4/2/19 to 5/19/21. This included 89 type and screens, 111 crossmatches, and transfusion of 94 red cell products to 56 patients. 2. Phone interview with TS #2 on 5/19/21 at 1:30 p.m. confirmed, the TS for immunohematology failed to ensure analytical performance was maintained at acceptable levels. D6118 TECHNICAL SUPERVISOR RESPONSIBILITIES CFR(s): 493.1451(b)(5) The technical supervisor is responsible for resolving technical problems and ensuring that remedial actions are taken whenever test systems deviate from the laboratory's established performance specifications. This STANDARD is not met as evidenced by: Based on review of 4/2/19 to 5/19/21 patient testing logs and interview, the TS for immunohematology failed to ensure remedial actions were taken whenever testing deviated from established performance. Findings: 1. No documentation of review by the TS for immunohematology of patient testing logs with test reactions and interpretation were available for 4/2/19 to 5/19/21. 2. Phone interview with TS #2 on 5 /19/21 at 1:30 p.m. confirmed, the TS for immunohematology failed to ensure remedial actions were taken whenever testing deviated from established performance. D6119 TECHNICAL SUPERVISOR RESPONSIBILITIES CFR(s): 493.1451(b)(6) The technical supervisor is responsible for ensuring that patient test results are not reported until all

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access