Stormont Vail Health Ob/Gyn-Lincoln Center,

CLIA Laboratory Citation Details

2
Total Citations
3
Total Deficiencyies
3
Unique D-Tags
CMS Certification Number 17D0923243
Address 800 Sw Lincoln St, Topeka, KS, 66606
City Topeka
State KS
Zip Code66606
Phone(785) 233-5101

Citation History (2 surveys)

Survey - November 28, 2023

Survey Type: Standard

Survey Event ID: 3SS411

Deficiency Tags: D6036

Summary:

Summary Statement of Deficiencies D6036 TECHNICAL CONSULTANT RESPONSIBILITIES CFR(s): 493.1413 The technical consultant is responsible for the technical and scientific oversight of the laboratory. This STANDARD is not met as evidenced by: Based on the review of the "Affirm Patient Test Log", "Monthly Quality Assurance Checklist", lack of documented

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - January 13, 2020

Survey Type: Standard

Survey Event ID: N0EH11

Deficiency Tags: D2009 D5433

Summary:

Summary Statement of Deficiencies D2009 TESTING OF PROFICIENCY TESTING SAMPLES CFR(s): 493.801(b)(1) The individual testing or examining the samples and the laboratory director must attest to the routine integration of the samples into the patient workload using the laboratory's routine methods. This STANDARD is not met as evidenced by: Based on a lack of proficiency testing (PT) attestation documentation from the provider American Proficiency Institute (API) performed after August 29, 2018 until date of survey and interview, the laboratory failed to attest on four of four testing events that proficiency testing samples were handled in the same manner as patient samples. Findings: 1. Attestation documentation for four of four proficiency testing events (listed below) from August 29, 2018 to January 13, 2020 was requested but none were availible at the time of survey. a. API 2018 Microbiology, 3rd Event. b. API 2019 Microbiology, 1st, 2nd, and 3rd Events 2. Interview with Technical Consultant (TC) #2 on January 13, 2020 at 1:35 p.m. confirmed, the laboratory failed to attest on four of four testing events that proficiency testing samples were handled in the same manner as patient samples. D5433 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(b)(1) For equipment, instruments, or test systems developed in-house, commercially available and modified by the laboratory, or maintenance and function check protocols are not provided by the manufacturer, the laboratory must establish a maintenance protocol that ensures equipment, instrument, and test system performance that is necessary for accurate and reliable test results and test result reporting. The laboratory must perform and document the maintenance activities specified in paragraph (b)(1)(i) of this section. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- This STANDARD is not met as evidenced by: Based on the review of manufacturer's test procedure requirements, lack of documentation, and interview, the laboratory failed to establish and perform a function check on their timer and two of two thermometers. Findings: 1. Review of the Affirm VP III Microbial Indentification test procedure revealed an incubation step that required the use of a timer. 2. Request was made to review the timer function check protocol and records. No documentation was available at the time of survey. 3. Request was made for two of two thermometer function check protocol and records. No documentation was available at the time of survey. 4. Interview with the TC #2 on January 13, 2020 at 1:15 p.m. confirmed, the laboratory failed to establish and perform a function check on their timer and two of two thermometers. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access