Teal Drive Lab

CLIA Laboratory Citation Details

1
Total Citation
2
Total Deficiencyies
1
Unique D-Tag
CMS Certification Number 21D2112250
Address 8221 Teal Drive Suite 410, Easton, MD, 21601
City Easton
State MD
Zip Code21601
Phone(410) 822-1000

Citation History (1 survey)

Survey - June 20, 2024

Survey Type: Standard

Survey Event ID: HVZF11

Deficiency Tags: D5413 D5413

Summary:

Summary Statement of Deficiencies D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: Based on review of the manufacturer's instructions for use (IFU), review of temperature logs, and interview with the technical consultant (TC), the laboratory failed to document humidity in the room where the hematology analyzer was operated for 17 of 17 months reviewed and the laboratory's acceptable range for room temperature did not match the manufacturer's specifications. Findings: 1. The laboratory performed hematology testing using a Sysmex XS-1000i analyzer. 2. The manufacturer's IFU stated "XS-1000i/XS-800i performance/specifications" for "Ambient temperature" as "15C to 30C (23C optimum)" and for "Relative humidity" as "30% to 85%." 3. Temperature records were reviewed for January 2023 through May 2024. 4. Relative humidity was not documented in 17 of 17 months reviewed. 5. The acceptable range for ambient temperature listed on the laboratory's temperature log was "10-30C." 6. During the exit interview on 06/20/2024 at 1:15 PM, the TC confirmed that relative humidity was not documented and that the lower value of the acceptable ambient temperature range listed on the laboratory's temperature log did not match the manufacturer's stated specifications. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access