Teaneck Pediatrics

CLIA Laboratory Citation Details

1
Total Citation
9
Total Deficiencyies
5
Unique D-Tags
CMS Certification Number 31D0113158
Address 197 Cedar Ln, Teaneck, NJ, 07666
City Teaneck
State NJ
Zip Code07666
Phone(201) 836-7171

Citation History (1 survey)

Survey - February 14, 2019

Survey Type: Standard

Survey Event ID: HQ6G11

Deficiency Tags: D5221 D5471 D5477 D5471 D5211 D5221 D6029 D5477 D6029

Summary:

Summary Statement of Deficiencies D5211 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(a) The laboratory must review and evaluate the results obtained on proficiency testing performed as specified in subpart H of this part. This STANDARD is not met as evidenced by: Based on surveyor review of the Proficiency Testing (PT) records and interview with the Laboratory Director (LD), the laboratory failed to review and evaluate coded PT results obtained from the College of American Pathologists (CAP) for UC Count Combo performed in the calendar year 2017 and 2018. The finding includes: 1. There was no evaluation documented when the laboratory received an exception code of 27 (no consensus) in event MC4 A 2017 and MC4 A 2018 for sample MC-02. 2. The LD confirmed on 2/14/19 at 1:30 pm that the laboratory did not review and evaluate coded PT results. D5221 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(d) All proficiency testing evaluation and verification activities must be documented. This STANDARD is not met as evidenced by: Based on surveyor review of the Proficiency Testing (PT) records and interview with the Laboratory Director (LD), the laboratory failed to evaluate results when the laboratory received an unacceptable score in PT for UC Count Combo performed with the College of American Pathologists (CAP) in 2018. The finding includes: 1. There was no review or evaluation documented when the laboratory received an Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- unacceptable result for MC-10 in the MC4-B 2018 event. 2. The LD confirmed on 2 /14/19 at 1:20 pm that the laboratory did not perform and document an evaluation of unacceptable PT performance. D5471 CONTROL PROCEDURES CFR(s): 493.1256(e)(1)(g) (e) For reagent, media, and supply checks, the laboratory must do the following: (e)(i) Check each batch (prepared in-house), lot number (commercially prepared) and shipment of reagents, disks, stains, antisera, (except those specifically referenced in 493.1261 (a)(3)) and identification systems (systems using two or more substrates or two or more reagents, or a combination) when prepared or opened for positive and negative reactivity, as well as graded reactivity, if applicable. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on surveyor review of the Quality Control (QC) records and interview with the Laboratory Director (LD), the laboratory failed to check each lot number and shipment of Bacitracin Discs for negative reactivity from 3/1/17 to the date of the survey. The LD confirmed on 2/14/19 at 2:20 pm that the above QC was not performed. D5477 CONTROL PROCEDURES CFR(s): 493.1256(e)(4)(g) (e) For reagent, media, and supply checks, the laboratory must do the following: (e) (4) Before, or concurrent with the initial use-- (e)(4)(i) Check each batch of media for sterility if sterility is required for testing; (e)(4)(ii) Check each batch of media for its ability to support growth and, as appropriate, select or inhibit specific organisms or produce a biochemical response; and (e)(4)(iii) Document the physical characteristics of the media when compromised and report any deterioration in the media to the manufacturer. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on the surveyor review of the Quality Control (QC) records and interview with the Laboratory Director (LD), the laboratory failed to check each new lot number and shipment of Urine Culture media for sterility, ability to support growth and select or inhibit organisms from 3/1/17 to the date of the survey. The LD confirmed on 2/14/19 at 2:30 pm the laboratory did not perform the above QC. Note: This deficiency was cited on the survey preformed on 3/1/17. The

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access