Terrence A Cronin Jr Md

CLIA Laboratory Citation Details

3
Total Citations
9
Total Deficiencyies
8
Unique D-Tags
CMS Certification Number 10D0928464
Address 1399 S Harbor City Blvd, Melbourne, FL, 32901
City Melbourne
State FL
Zip Code32901
Phone321 726-1711
Lab DirectorTERRENCE JR

Citation History (3 surveys)

Survey - March 6, 2023

Survey Type: Standard

Survey Event ID: CR0D11

Deficiency Tags: D0000 D5609

Summary:

Summary Statement of Deficiencies D0000 A Rcertification survey was conducted on March 6, 2023. Terrence A Cronin Jr MD clinical laboratory was not in compliance with 42 CFR 493, requirements for clinical laboratories. D5609 HISTOPATHOLOGY CFR(s): 493.1273(e)(f) (e) The laboratory must use acceptable terminology of a recognized system of disease nomenclature in reporting results. (f) The laboratory must document all control procedures performed, as specified in this section. This STANDARD is not met as evidenced by: Based on record review and interview, the laboratory failed to document quality control (QC) information including open dates for all reagents used in their Hematoxylin & Eosin (H & E), from March 2021 to April 2022. Findings: The laboratory used the following reagents in their H&E stain: Scott Tap Water, 100% Reagent Alcohol, Gill's Hematoxylin III, and Eosin Working Solution. Review of the laboratory's procedure manual noted for 493.1273" QC records should include lot numbers, date opened/prepared, expiration dates . . . " Review of the laboratory's QC logs titled "Reagent Control Sheet" showed there were no open dates for reagents used prior to the reagents currently being used. On 03/06/2023 at 10:50 AM, Mohs Technician B acknowledged the open dates were not recorded. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - March 25, 2021

Survey Type: Standard

Survey Event ID: TK7511

Deficiency Tags: D3031 D0000

Summary:

Summary Statement of Deficiencies D0000 A recertification survey was conducted on March 25, 2021. Terrence A Cronin Jr MD clinical laboratory was not in compliance with 42 CFR 493, requirements for clinical laboratories. D3031 RETENTION REQUIREMENTS CFR(s): 493.1105(a)(3) Analytic systems records. Retain quality control and patient test records (including instrument printouts, if applicable) and records documenting all analytic systems activities specified in 493.1252 through 493.1289 for at least 2 years. This STANDARD is not met as evidenced by: Based on record review and interview, the laboratory failed to retain Quality Control (QC) records for the histopathology laboratory from 03/25/2019 to 07/09/2021. Findings: Review of the laboratory's QC records showed the records for recording the Hematoxylin and Eosin stain maintenance and stain quality, the cryostat temperature and maintenance, the room temperature and humidity, and the reagent logs were not available for review. The Application for Certification signed and dated by the Laboratory Director on 03/24/21, noted the laboratory had an estimated annual test volume of 1,472 histopathology tests per year. During an interview on 03/25/2021 at 12:51 PM, the Laboratory Consultant stated they were unable to locate the missing logs. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - January 23, 2019

Survey Type: Standard

Survey Event ID: 7W5G11

Deficiency Tags: D5200 D5217 D3011 D5209 D5413

Summary:

Summary Statement of Deficiencies D3011 FACILITIES CFR(s): 493.1101(d) Safety procedures must be established, accessible, and observed to ensure protection from physical, chemical, biochemical, and electrical hazards, and biohazardous materials. This STANDARD is not met as evidenced by: Based on record review and interview, the laboratory failed to dispose of chemicals per manufacturer's instructions for 2 out of 2 years reviewed (1/23/17 to 1/23/19). Findings: Review of the manufacturer's instructions on the bottle of 100% Reagent Alcohol read, "Contact a licensed professional waste disposal service to dispose of this material." Manufacturer's instructions on the bottle of Histo-Clear read, "Dispose of contents/container to an approved waste disposal plant." The laboratory's procedure titled "Disposal of Non-Toxic Reagents" read, "Due to the fact that all our reagents are non-toxic non-xylene based, all spent reagents are greatly diluted and washed down the drain with lots of water." During an interview on 1/23/19 at 2:03 PM, the Mohs Technician confirmed that the chemical reagents are disposed down the sink drain, and did not follow the manufacturer's instructions from 1/23/17 to 1/23/19. D5200 GENERAL LABORATORY SYSTEMS CFR(s): 493.1230 Each laboratory that performs nonwaived testing must meet the applicable general laboratory systems requirements in 493.1231 through 493.1236, unless HHS approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing. The laboratory must monitor and evaluate the overall quality of the general laboratory systems and correct identified problems specified in 493.1239 for each specialty and subspecialty of testing performed. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- This CONDITION is not met as evidenced by: Based on record review and interview, the laboratory's quality assessment program failed to monitor and evaluate the overall quality of the general laboratory system and correct problems identified. The laboratory failed to document annual competency assessment on the Mohs technician for 2017 and 2018. This is a repeat deficiency from the survey performed in 2017. Findings: 1. Cross Reference D5209. Based on record review and staff interview, the laboratory failed to document annual competency assessment on the Mohs Technician for 2017 and 2018. This is a repeat deficiency from the survey performed in 2017. 2. Cross Reference D5217. Based on record review and staff interview, the laboratory failed to verify the accuracy of the reading and interpretation of the Hematoxylin and Eosin (H&E) stain in 2018 at least twice annually. D5209 PERSONNEL COMPETENCY ASSESSMENT POLICIES CFR(s): 493.1235 As specified in the personnel requirements in subpart M, the laboratory must establish and follow written policies and procedures to assess employee and, if applicable, consultant competency. This STANDARD is not met as evidenced by: Based on record review and staff interview, the laboratory failed to document annual competency assessment on the Mohs Technician for 2017 and 2018. This is a repeat deficiency from the survey performed in 2017. Findings: Review of the competency records showed that the laboratory failed to have documentation of annual competency assessments for one out of one Mohs technician in 2017 and 2018. During an interview on 1/23/19 at 2:33 PM, Mohs Technician stated that he did have a competency evaluation in 2017 or 2018 but could not provide evidence of this. D5217 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(1) At least twice annually, the laboratory must verify the accuracy of any test or procedure it performs that is not included in subpart I of this part. This STANDARD is not met as evidenced by: Based on record review and staff interview, the laboratory failed to verify the accuracy of the reading and interpretation of the Hematoxylin and Eosin (H&E) stain in 2018 at least twice annually. Findings: The laboratory uses peer review to verify the accuracy of the reading and interpretation H&E stain. Review of the laboratory's records showed that peer review was performed on 12/31/18 for testing person A. The procedure titled "Proficiency Testing" read that slides will be sent twice yearly. During an interview on 1/23/19 at 3:50 PM, the Office Manager stated that peer review was sent out in late spring or early summer but was unable to provide the documentation. D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper -- 2 of 3 -- storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: Based on record review and interview, the laboratory failed to record the temperature and humidity of the room where testing was performed from 1/23/17 to 1/23/19. Findings: Review of the laboratory's logs showed that the laboratory failed to record the room temperature and humidity of the room where testing was performed from 1 /23/17 to 1/23/19. During a interview on 1/23/19 at 1:35 PM, the Mohs Technician acknowledged that they did not record the temperature or humidity of the laboratory. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access