Texas Avenue Medical Clinic

CLIA Laboratory Citation Details

2
Total Citations
17
Total Deficiencyies
9
Unique D-Tags
CMS Certification Number 45D0718803
Address 1703 East 29th St, Bryan, TX, 77802
City Bryan
State TX
Zip Code77802
Phone(979) 779-4756

Citation History (2 surveys)

Survey - June 6, 2022

Survey Type: Standard

Survey Event ID: EHV111

Deficiency Tags: D0000 D6053 D6063 D6065 D0000 D6053 D6063 D6065

Summary:

Summary Statement of Deficiencies D0000 The laboratory was surveyed and failed to meet the following conditions of the CLIA regulations f 493. 1421 Condition: Laboratories Performing Moderate Complexity Testing; Testing Personnel D6053 TECHNICAL CONSULTANT RESPONSIBILITIES CFR(s): 493.1413(b)(9) The technical consultant is responsible for evaluating and documenting the performance of individuals responsible for moderate complexity testing at least semiannually during the first year the individual tests patient specimens. This STANDARD is not met as evidenced by: Review of personnel files and interview of facility personnel found that the technical consultant failed to perform competency assessments at least semiannually during the first year of patient testing for one of seven testing personnel listed on the CMS report 209 Laboratory Personnel Report. Findings were as follows: 1. Review of personnel files found that testing person one had completed initial training on May 14, 2021. There was no documentation of competency assessment performance available for review. 2. Interview of testing person 7 listed on the CMS report 209 Laboratory Personnel Report conducted on June 6, 2022 at 9:12 AM confirmed that competency assessments for testing person one were not performed at least semiannually during the first year of patient testing. D6063 LABORATORY TESTING PERSONNEL CFR(s): 493.1421 The laboratory must have a sufficient number of individuals who meet the qualification requirements of 493.1423, to perform the functions specified in 493. 1425 for the volume and complexity of tests performed. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- This CONDITION is not met as evidenced by: Review of the CMS Report 209 Laboratory Personnel Report, personnel records and interview of facility personnel found that the laboratory director failed to ensure that all testing personnel had the minimum education requirements for performing moderate complexity testing prior to testing patient specimens. (See D6065) D6065 TESTING PERSONNEL QUALIFICATIONS CFR(s): 493.1423(b)(1)(2)(3)(4)(i) (b) Meet one of the following requirements: (b)(1) Be a doctor of medicine or doctor of osteopathy licensed to practice medicine or osteopathy in the State in which the laboratory is located or have earned a doctoral, master's, or bachelor's degree in a chemical, physical, biological or clinical laboratory science, or medical technology from an accredited institution; or (b)(2) Have earned an associate degree in a chemical, physical or biological science or medical laboratory technology from an accredited institution; or (b)(3) Be a high school graduate or equivalent and have successfully completed an official military medical laboratory procedures course of at least 50 weeks duration and have held the military enlisted occupational specialty of Medical Laboratory Specialist (Laboratory Technician); or (b)(4)(i) Have earned a high school diploma or equivalent; and This STANDARD is not met as evidenced by: Based on a review of laboratory records and staff interview, one of seven testing personnel did not have the appropriate education credentials required to perform moderate complexity testing. The findings included: 1. Review of laboratory records found no documentation of education for testing person one listed on the CMS report 209. Testing person one was hired May 14, 2021. 2. Interview of testing person 7 conducted June 6, 2022 at 9:28 AM confirmed that education records were not available for review for testing person number one. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - March 25, 2021

Survey Type: Standard

Survey Event ID: 7DSR11

Deficiency Tags: D2009 D5411 D5421 D5429 D5429 D1000 D2009 D5411 D5421

Summary:

Summary Statement of Deficiencies D1000 CERTIFICATE OF WAIVER TESTS CFR(s): 493.15(c) Certificate of waiver tests. A laboratory may qualify for a certificate of waiver under section 353 of the PHS Act if it restricts the tests that it performs to one or more of the following tests or examinations (or additional tests added to this list as provided under paragraph (d) of this section) and no others: (1) Dipstick or Tablet Reagent Urinalysis (non-automated) for the following: (i) Bilirubin; (ii) Glucose; (iii) Hemoglobin; (iv) Ketone; (v) Leukocytes; (vi) Nitrite; (vii) pH; (viii) Protein; (ix) Specific gravity; and (x) Urobilinogen. (2) Fecal occult blood; (3) Ovulation tests-visual color comparison tests for human luteinizing hormone; (4) Urine pregnancy tests - visual color comparison tests; (5) Erythrocyte sedimentation rate-non-automated; (6) Hemoglobin- copper sulfate-non-automated; (7) Blood glucose by glucose monitoring devices cleared by the FDA specifically for home use; (8) Spun microhematocrit; and (9) Hemoglobin by single analyte instruments with self-contained or component features to perform specimen/reagent interaction, providing direct measurement and readout. This STANDARD is not met as evidenced by: I. Based on review of manufacturer's instructions, observation, and interview, the laboratory failed to follow manufacturer's instructions for the glucose monitoring of diabetic patients for home use only using the Contour Next blood glucose meter. Findings follow. 1. Review of the Contour Next User Guide under Indications for Use stated, "the Contour Next blood glucose monitoring system is an over-the-counter device utilized by persons with diabetes in home settings for the quantitative measurement of glucose in whole blood, and is for single-patient use only, and should not be shared." 2. Surveyor observed on March 25, 2021 the Contour Next glucose monitor in the drawer in the hall laboratory. 3. Interview with testing personnel #2, on the CMS Form 209, on March 25, 2021 at 1410 hours in the hall laboratory confirmed the Contour Next was the glucose monitor in use in the clinic. II. Based on review of observation, manufacturer's instructions, and interview, the laboratory failed to follow Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- manufacturer's instructions by using expired test strips for the Contour Next blood glucose meter. Findings follow. 1. Surveyor observed on March 25, 2021 the open vial of Contour Next blood glucose strips for self-testing, Lot DWBDPEB51B, located in the drawer of the hall laboratory had an expiration date of 04/30/2020. 2. Interview with testing personnel #2, on the CMS Form 209, on March 25, 2021 at 1410 hours in the hall laboratory confirmed the Contour Next blood glucose test strips were the strips currently in use in the laboratory. D2009 TESTING OF PROFICIENCY TESTING SAMPLES CFR(s): 493.801(b)(1) The individual testing or examining the samples and the laboratory director must attest to the routine integration of the samples into the patient workload using the laboratory's routine methods. This STANDARD is not met as evidenced by: Based on review of the laboratory's American Proficiency Testing (API) proficiency testing (PT) records, and confirmed in interview of facility personnel, the laboratory failed to provide documentation of 2 of 6 attestation statements being signed by those who were required to sign them. The findings were: 1. Review of API's attestation statement form 2019 (events 1, 2, and 3) and 2020 (events 1, 2, 3) stated, "Testing personnel and the laboratory director must physically sign an attestation statement for all PT results, and retain the signed statement (or a copy) for a minimum of 2 years. Either the attestation statement below or a printed copy of the form provided online can be used for this purpose." 2. Review of the laboratory's API proficiency testing records from 2019 (events 1, 2, and 3) and 2020 (events 1, 2, and 3) found the following attestation statements were not signed: 2019 (event 1) not signed by laboratory director or testing person 2020 (event 3) not signed by laboratory director 3. An interview with testing personnel #1 (as listed on Form CMS-209) at 15:30 hours in the office confirmed the findings D5411 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(a) Test systems must be selected by the laboratory. The testing must be performed following the manufacturer's instructions and in a manner that provides test results within the laboratory's stated performance specifications for each test system as determined under 493.1253. This STANDARD is not met as evidenced by: Based on review of the manufacturer's instructions, test reports, and interview, the laboratory failed to redact the result, or confirm test results for "marks" on the Complete Blood Count test report using the Sysmex XN-330 hematology analyzer. Findings follow. 1. Review of the Sysmex XN-330 Basic Operation manual, June 2017, under "5.11.2 Display of analysis result data" starting on page 5-22 stated, "When an analysis result could not be obtained due an error or other problem, the result is masked. When as analysis result is determined to be abnormal, a mark appears." Under Marks the * (asterisk) is shown with the Meaning of "low reliability." 2. Review of 1 of 1 patient test reports with a "mark" sample number 7 tested on 02/05 /2021 with the * asterisks on the test results for PLT (platelets) and MPV (mean platelet volume). 3. Interview with testing personnel #2, on the CMS form 209, on -- 2 of 3 -- March 25, 2021 at 1705 hours in the conference room confirmed the physician looks at the test report and they send the sample to the reference lab. The patient was a self- pay patient and cancelled the additional lab work. Interview with testing personnel #1 on March 25, 2021 at 1710 hours in the conference room agreed to send an example of a patient test report with a "mark" sent to a reference lab. No examples were received as of report date April 5, 2021. D5421 ESTABLISHMENT AND VERIFICATION OF PERFORMANCE CFR(s): 493.1253(b)(1) Each laboratory that introduces an unmodified, FDA-cleared or approved test system must do the following before reporting patient test results: (1)(i) Demonstrate that it can obtain performance specifications comparable to those established by the manufacturer for the following performance characteristics: (1)(i)(A) Accuracy. (1)(i) (B) Precision. (1)(i)(C) Reportable range of test results for the test system. (1)(ii) Verify that the manufacturer's reference intervals (normal values) are appropriate for the laboratory's patient population. This STANDARD is not met as evidenced by: Based on review of the verification of performance specifications, and interview, the laboratory failed to verify the normal patient reference range for the Complete Blood Count using the Sysmex XN-330 hematology analyzer. Findings follow. 1. Review of the Sysmex XN-330 verifications of performance specifications performed at installation on Jan 8 & 9, 2020 showed no documentation of the verification of the normal patient reference range. The normal reference range was requested but not provided. 2. Interview with testing personnel #1, on the CMS Form 209, on March 25, 2021 at 1700 hours acknowledged she had no idea whether the verification of the normal reference range had been verified. D5429 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(a)(1) For unmodified manufacturer's equipment, instruments, or test systems, the laboratory must perform and document maintenance as defined by the manufacturer and with at least the frequency specified by the manufacturer. This STANDARD is not met as evidenced by: Based on review of the maintenance logs, observation and interview, the laboratory failed to document maintenance on the Sysmex XN-330 hematology analyzer used to test Complete Blood Counts for 5 of 15 months reviewed. Findings follow. 1. Review of the XN-330 Maintenance log from Jan 2020 - current, showed no logs for: a. Oct 2020, b. Nov 2020, c. Dec 2020, d. Feb 2021, and e. March 2021. 2. Surveyor observed on March 25, 2021 at 1550 hours in the conference room, the January 2021 XN-330 Maintenance log showed the tech initials were of the same handwriting for maintenance performed by 5 different testing personnel. 3. Interview with testing personnel #1, on the CMS Form 209, on March 25, 2021 at 1550 hours in the conference room confirmed there were missing maintenance logs, and no current maintenance log for March 2021. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access