The Iowa Clinic - Indianola

CLIA Laboratory Citation Details

3
Total Citations
9
Total Deficiencyies
9
Unique D-Tags
CMS Certification Number 16D2073760
Address 1504 North 1st Street, Indianola, IA, 50125
City Indianola
State IA
Zip Code50125
Phone515 875-9502
Lab DirectorCURTIS MCCARTY

Citation History (3 surveys)

Survey - January 6, 2026

Survey Type: Special

Survey Event ID: XDCH11

Deficiency Tags: D0000 D2016 D2130 D6000 D6016

Summary:

Summary Statement of Deficiencies D0000 A proficiency testing desk review survey was completed on January 06, 2026. The laboratory was found to be out of compliance with the following CONDITION LEVEL DEFICIENCIES: D2016 - 42 C.F.R 493.803 Condition: Successful Participation D6000 - 42 C.F.R 493.1403 Condition: Laboratory Director, Moderate Complexity D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on review of the Certification and Survey Provider Enhanced Reporting (CASPER) 155 report and graded results from the American Proficiency Institute, the laboratory failed to successfully participate in two consecutive testing events for the Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- analyte, red blood cell count. The laboratory had unsatisfactory scores for 2025 events 2 and 3. Refer to D2130. D2130 HEMATOLOGY CFR(s): 493.851(f) (f) Failure to achieve satisfactory performance for the same analyte in two consecutive events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on review of the Certification and Survey Provider Enhanced Reporting (CASPER) 155 report and graded results from the American Proficiency Institute (API), the laboratory failed to successfully participate in two consecutive testing events for the analyte, red blood cell count. The findings include: 1. For 2025 event 2, the laboratory received an unsatisfactory performance score of 60% for the analyte, red blood cell count. 2. For 2025 event 3, the laboratory received an unsatisfactory performance score of 60% for the analyte, red blood cell count. 3. The CASPER 155 report and graded results from API confirm the findings listed above. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on review of the Certification and Survey Provider Enhanced Reporting (CASPER) 155 report and graded results from the American Proficiency Institute (2025 events 2 and 3), the laboratory director failed to provide overall management and direction of the laboratory services. Refer to D6016. D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) (e)(4)(i) The proficiency testing samples are tested as required under Subpart H of this part; This STANDARD is not met as evidenced by: Based on review of the Certification and Survey Provider Enhanced Reporting (CASPER) 155 report and graded results from the American Proficiency Institute (API), the laboratory director failed to ensure successful participation in an HHS approved proficiency testing program. Refer to D2130. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - March 8, 2022

Survey Type: Standard

Survey Event ID: NI8811

Deficiency Tags: D6054

Summary:

Summary Statement of Deficiencies D6054 TECHNICAL CONSULTANT RESPONSIBILITIES CFR(s): 493.1413(b)(9) The technical consultant is responsible for evaluating and documenting the performance of individuals responsible for moderate complexity testing at least annually, after the first year. This STANDARD is not met as evidenced by: Based on review of personnel records and confirmed by the Clinical Laboratory Manager at approximately 11:45 am on 03/08/2022, the technical consultant failed to assess and document the competency of individuals performing moderate complexity testing (complete blood count) at least annually for three out of three testing personnel (personnel identifiers #2- #4) in 2020 and 2021. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - February 4, 2020

Survey Type: Standard

Survey Event ID: FE3Q11

Deficiency Tags: D3031 D5781 D5785

Summary:

Summary Statement of Deficiencies D3031 RETENTION REQUIREMENTS CFR(s): 493.1105(a)(3) Analytic systems records. Retain quality control and patient test records (including instrument printouts, if applicable) and records documenting all analytic systems activities specified in 493.1252 through 493.1289 for at least 2 years. This STANDARD is not met as evidenced by: Based on review of the Medonic hematology analyzer background checks and confirmed by laboratory personnel identifer #2 (refer to the Laboratory Personnel Report) at approximately 2:00 pm on 2/4/2020, the laboratory failed to retain the hematology background check records for four out of 42 days of patient testing (9/3 /2019, 9/5/2019, 9/25/2019, and 10/3/2019) in September and October 2019. The findings include: 1. The laboratory performed a background check on the Medonic hematology analyzer each day of patient testing. 2. Laboratory personnel then placed the background check in the specific folder for each month. 3. At the time of the survey, the laboratory did not have background checks for 9/3/2019, 9/5/2019, 9/25 /2019, and 10/3/2019. D5781

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility