Citation History (3 surveys)

Survey - April 30, 2026

Survey Type: Standard

Survey Event ID: Z7O611

Deficiency Tags: D5215 D5407

Summary:

Summary Statement of Deficiencies D5215 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(b)(2) The laboratory must verify the accuracy of any analyte, specialty or subspecialty assigned a proficiency testing score that does not reflect laboratory test performance (that is, when the proficiency testing program does not obtain the agreement required for scoring as specified in subpart I of this part, or the laboratory receives a zero score for nonparticipation, or late return or results). This STANDARD is not met as evidenced by: Based on surveyor review of laboratory proficiency testing (PT) records from the American Proficiency Institute (API) PT program and interview with a technical consultant (Staff A), the laboratory did not identify that the laboratory's results fell outside of the expected range and did not verify the accuracy of the total bilirubin test for two of three PT events in 2025, when the PT program did not obtain the agreement required for scoring and provided "Not Graded" results. Findings include: 1. Review of the API PT Performance Evaluation reports for two chemistry-core PT events in 2025 for total bilirubin revealed the laboratory received three "Not Graded" scores in event two, and two "Not Graded" scores in event three. The reports from the two events showed the following samples received a "Not Graded" score for the total bilirubin test: Sample | Reported Result | Expected Result PT Event 2-2025 CH-07 | 3.1 | 1.8-2.9 CH-09 | 2.2 | 1.3-2.2 CH-10 | 4.0 | 2.4-3.7 PT Event 3-2025 CH-12 | 2.4 | 1.4-2.3 CH-15 | 1.7 | 1.0-1.9 Further review of the report revealed the laboratory's results were not within the expected result range for samples CH-07, CH-10, and CH- 12. There was no evidence the laboratory took action to investigate and verify the accuracy of the total bilirubin test. 2. Interview with Staff A on April 30, 2026, at 11: 50 AM confirmed the laboratory received "Not Graded" results on the two PT events for total bilirubin and confirmed the laboratory did not verify the accuracy for the total bilirubin samples in the two PT events when the PT program did not obtain the agreement required for scoring. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- D5407 PROCEDURE MANUAL CFR(s): 493.1251(d) (d) Procedures and changes in procedures must be approved, signed, and dated by the current laboratory director before use. This STANDARD is not met as evidenced by: Based on surveyor review of a 'Centers for Medicare and Medicaid Services (CMS) Clinical Laboratory Improvement Amendments (CLIA) Application for Certification' form (Form CMS-116) and the laboratory's procedure manual, and interview with a technical consultant (Staff A), the current laboratory director failed to approve the laboratory's procedure manual since assuming the role of laboratory director, including for four of four random procedures reviewed. Findings include: 1. Review of a Form CMS-116 submitted to the State CLIA office showed the laboratory requested a laboratory director change to Staff B effective October 1, 2025. 2. Review of four of the laboratory's procedures revealed no evidence the current laboratory director had approved the procedures for performing testing on the Beckman Coulter AU 680 analyzer, performing serum pregnancy testing, including the serum pregnancy individualized quality control plan (IQCP), and the Siemens DCA Vantage analyzer IQCP. 3. Interview with Staff A on April 30, 2026, at 12:38 PM confirmed the current laboratory director had not approved, signed, and dated the laboratory procedures since assuming the laboratory director role. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - September 10, 2020

Survey Type: Standard

Survey Event ID: ZR6U11

Deficiency Tags: D5783 D6046 D6046

Summary:

Summary Statement of Deficiencies D5783

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - February 22, 2018

Survey Type: Standard

Survey Event ID: R4WX11

Deficiency Tags: D5447

Summary:

Summary Statement of Deficiencies D5447 CONTROL PROCEDURES CFR(s): 493.1256(d)(3)(i)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- At least once a day patient specimens are assayed or examined perform the following for-- Each quantitative procedure, include two control materials of different concentrations; (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on surveyor review of laboratory quality control records and interview with the laboratory Technical Consultant the laboratory does not use an elevated serum bilirubin control for monitoring the abnormal range of neonatal bilirubin testing. Findings include: 1. Review of laboratory quality control (QC) records for the bilirubin assay show that two levels of QC are performed on a daily basis. The QC records for the bilirubin assay show that an elevated serum based bilirubin control for monitoring the abnormal range of neonatal bilirubin's is not assayed when performing neonatal bilirubin testing. 2. Interview with the Technical Consultant on February 22, 2018 at 12:30 PM confirms that an elevated serum based bilirubin control is not used to monitor the abnormal range of neonatal bilirubin's. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --