Thompson Oncology Group

CLIA Laboratory Citation Details

2
Total Citations
5
Total Deficiencyies
5
Unique D-Tags
CMS Certification Number 44D1006416
Address 1915 White Avenue, Knoxville, TN, 37916
City Knoxville
State TN
Zip Code37916
Phone865 331-2373
Lab DirectorRUSSELL TIPTON

Citation History (2 surveys)

Survey - July 22, 2026

Survey Type: Standard

Survey Event ID: LN3113

Deficiency Tags: D3011 D5413

Summary:

Summary Statement of Deficiencies D3011 FACILITIES CFR(s): 493.1101(d) Safety procedures must be established, accessible, and observed to ensure protection from physical, chemical, biochemical, and electrical hazards, and biohazardous materials. This STANDARD is not met as evidenced by: Based on laboratory observations and staff interviews, the facility failed to follow posted safety signage by storing food for human consumption in a freezer designated for biohazards on the survey date (07.22.2026). The findings include: 1. Observation of the laboratory on 07.22.2026 at 9:10 a.m. revealed the Sysmex XN-530 (serial number 12248) Hematology analyzer and the Medica EasyRA (serial number 20423040519) Chemistry analyzer used for patient testing. Also observed, at 9:25 a. m., in the blood collection area, was a refrigerator/freezer with safety signage that read "Biohazard no food or drink to be stored in this refrigerator or freezer." The freezer contained a pint of ice cream for human consumption. 2. An interview on 07.22.2026 at 9:30 a.m. with the two technical consultants confirmed the above survey findings. D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) (b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (b)(1) Water quality. (b)(2) Temperature. (b)(3) Humidity. (b)(4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- reports. This STANDARD is not met as evidenced by: Based on direct observation, a review of the manufacturer's storage requirements, lack of documentation, and staff interviews, the laboratory failed to ensure proper temperature storage for blood collection tubes on the date of the survey (07.22.2026). The findings include: 1. Observation of the blood collection room on 07.22.2026 at 9: 10 a.m. revealed the following blood collection tubes stored in the cabinet: -16 Becton Dickinson (BD) Vacutainer 4mL dipotassium Ethylenediaminetetraacetic Acid (K2E) tubes -24 BD Vacutainer 3mL Gel and Lithium Heparin (LH) tubes -60 BD Vacutainer 2.7mL Buffered Sodium Citrate tubes -64 BD Vacutainer 6.0 mL serum tubes -100 BD Vacutainer 6.0 mL K2E tubes -5 BD Vacutainer 6.0 mL Trace Element Serum tubes Observed in a cabinet in the adjoining hallway revealed the following blood collection tubes; -9 packs, containing 100 tubes per pack, BD Vacutainer 4mL K2E tubes -2 packs, containing 100 tubes per pack, BD Vacutainer 3 mL Gel and LH tubes -3 packs, containing 100 tubes per pack, BD Vacutainer 5.0mL Sodium Separator Tube (SST) tubes 2. A review of the BD Vacutainer manufacturer's storage requirements revealed that the acceptable temperature range for tube storage is 4C to 25C. 3. A request for environmental records for the blood collection room and adjoining hallway revealed no records available for surveyor review on the survey date, 07.22.2026. 4. An interview with the two technical consultants on 07.22.2026 at 9:30 a.m. confirmed the above survey findings. Word Key: C = degrees Celsius mL = milliliters -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - June 4, 2025

Survey Type: Standard

Survey Event ID: LN3111

Deficiency Tags: D5461 D5781 D6030

Summary:

Summary Statement of Deficiencies D5461 CONTROL PROCEDURES CFR(s): 493.1256(d)(6)(g) (d)(6) Perform control material testing as specified in this paragraph before resuming patient testing when a complete change of reagents is introduced; major preventive maintenance is performed; or any critical part that may influence test performance is replaced. This STANDARD is not met as evidenced by: Based on laboratory observation, review of the reagent log, review of quality control records, and staff interview, the laboratory failed to perform quality control (QC) after changing reagents on the Sysmex XS-1000i complete blood count (CBC) analyzer in October 2023 and May 2025. The findings include: 1. Observation of the laboratory on 06.04.2025 at 9:00 a.m. revealed a Sysmex XS-1000i (Serial Number 70754) hematology analyzer used for complete blood count (CBC) patient testing. 2. A review of the Sysmex XS-1000i reagent log revealed that the laboratory changed reagents on the analyzer on 10.06.2023 at 4:45 p.m. and 05.14.2025 at 1:24 p.m. 3. A review of the Sysmex XS-1000i quality control records revealed no documentation that the laboratory ran QC after changing reagents on 10.06.2023 (QC lot 3261) and 05.14.2025 (QC lot 5090). 4. An interview with the technical consultant on 06.04.2025 at 12:30 p.m. confirmed the above survey findings. D5781