Tower Nephrology Medical Group

CLIA Laboratory Citation Details

1
Total Citation
6
Total Deficiencyies
6
Unique D-Tags
CMS Certification Number 05D0937918
Address 8641 Wilshire Blvd, Ste 300, Beverly Hills, CA, 90211
City Beverly Hills
State CA
Zip Code90211
Phone(310) 652-9162

Citation History (1 survey)

Survey - July 5, 2019

Survey Type: Standard

Survey Event ID: JW5511

Deficiency Tags: D2098 D5217 D6053 D2020 D5215 D6019

Summary:

Summary Statement of Deficiencies D2020 BACTERIOLOGY CFR(s): 493.823(a) Failure to attain an overall testing event score of at least 80 percent is unsatisfactory performance. This STANDARD is not met as evidenced by: Based on review of Q2-2018 of the Medical Laboratory Evaluation (MLE) proficiency summary report, random patient sampling reports, and interview with the testing personnel; it was determined that the laboratory failed to attain an overall testing event score of at least 80 percent is unsatisfactory performance. The findings included: a. Q-2-2018, MLE reported unsatisfactory proficiency score of 60% for Bacterial Identification. b. For eight (8) out of eight (8) random patient test results reviewed covering period 12/6/2017 to 5/9/2019, the laboratory analyzed and reported eight patients for bacterial identification during the period in which the laboratory received the failed proficiency score. c. The testing personnel confirmed (7/5/2019, 1430) that the laboratory received the above unsatisfactory proficiency score. D2098 ENDOCRINOLOGY CFR(s): 493.843(a) Failure to attain a score of at least 80 percent of acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the testing event. This STANDARD is not met as evidenced by: Based on review of Q3-2018 of the American Association of Bioanalysts (AAB) proficiency summary report, random patient sampling reports, and interview with the testing personnel; it was determined that the laboratory failed to attain a score of at least 80 percent of acceptable responses for each analyte in each testing event is Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 4 -- unsatisfactory analyte performance for the testing event. The finding included: a. Q3- 2018, AAB reported unsatisfactory proficiency score of 60% for Thyroid Stimulating Hormone (TSH) analyte. b. For two (2) out of eleven (11) random patient test results reviewed covering period 6/23/2017 to 6/28/2019, two (2) patients had TSH analytes that the laboratory analyzed and reported during the period that the laboratory received the unsatisfactory proficiency testing score. c. The testing personnel confirmed (7/5/2019, 1430) that the laboratory received the above unsatisfactory proficiency score. D5215 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(b)(2) The laboratory must verify the accuracy of any analyte, specialty or subspecialty assigned a proficiency testing score that does not reflect laboratory test performance (that is, when the proficiency testing program does not obtain the agreement required for scoring as specified in subpart I of this part, or the laboratory receives a zero score for nonparticipation, or late return or results). This STANDARD is not met as evidenced by: Based on review of first quarter (Q1-2018) and (Q2-2018) of the American Association of Bioanalysts (AAB ) proficiency testing reports, laboratory proficiency testing records and interview with the testing personnel, the laboratory failed to have a mechanism to review proficiency testing results that have an artificial score of 100% even though the laboratory's reported results were outside the grading range. The findings included: a. The laboratory received an artificial score of 100% for Parathyroid Hormone (PTH) for the (Q1-2018, Q2-2018). The AAB proficiency test footnote reports revealed that for results with prefix codes indicated the following statement:? = "This score may not truly evaluate performance for this specimen which was not graded because of a lack of participant consensus." The following proficiency samples were analyzed and reported by the laboratory: PTH Q1-2018 Specimen: Value. Mean: Grading Score: Reported Range: Spec: 1? 1.2 5.11 3.8-6.4 100% Spec: 2? 2.6 20.81 15.6-26 100% Q2-2018 Specimen: Value. Mean: Grading Score: Reported Range: Spec: 1? 6.9 17.77 13.3-22.2 100% Spec: 2? 6.3 16.13 12.1-20.2 100% Note: True scores for PTH is 0% The laboratory received an artificial score of 80% for High Density Lipoprotein (HDL)) for the (Q1-2018, Q2-2018). The AAB proficiency test footnote reports revealed that for results with prefix codes indicated the following statement: # = "This method was not graded due to an insufficient number of peer respondents. No appropriate default grouping was available. The listed range should provide a reasonable guide to your performance. However, exercise caution in evaluating your records." The following proficiency samples were analyzed and reported by the laboratory: HDL Q1-2018 Specimen: Value. Mean: Grading Reported Range: Spec: 1 # 64 34.8 24-45 Spec: 2 # 151 107.1 75-139 Spec: 3 # 89 46.6 33-61 Spec: 4 # 30 17.8 12-23 Q2-2018 Specimen: Value. Mean: Grading Score: Reported Range: Spec: 1 # 28 16.9 12-22 Spec: 2 # 79 43.5 30-57 Spec: 4 # 14 8.9 6-12 Spec: 5# 60 33.4 23-43 Note: True scores for HDL 0% b. For two (2) out of two (2) random patient test results reviewed for PTH and for five (5) out of five (5) random patient test results reviewed for HDL covering period from 6/23/2017-6/28 /2019, two (2) patients for PTH and for five (5) patients for HDL were analyzed and reported during the time which the laboratory received an artificial 100% scores which did not reflect the true passing scores for the laboratory's proficiency testing. c. -- 2 of 4 -- The testing personnel confirmed (7/5/2019, 1430) that the laboratory received the above artificial 100% passing scores even though the reported results were outside the grading range for PTH and HDL analytes. D5217 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(1) At least twice annually, the laboratory must verify the accuracy of any test or procedure it performs that is not included in subpart I of this part. This STANDARD is not met as evidenced by: Based on review of Q3-2017 and Q3-2018 of the American Association of Bioanalysts (AAB) proficiency summary reports, random patient sampling reports, and interview with the testing personnel; it was determined that the laboratory failed to at least twice annually, the laboratory must verify the accuracy of any test or procedure it performs that is not included in subpart I of this part. The findings included: a. Q-3 2017, Q-2018 AAB reported unsatisfactory proficiency score of 50% for Urine sediments. b. For nine (9) out of ten (10) random patient test results reviewed covering period 6/23/2017 to 6/28/2019, seven (7) patients had urinalysis microscopic in which results cannot be assured due to the laboratory's unsatisfactory proficiency report. c. The testing personnel confirmed (7/5/2019, 1430) that the laboratory received the above unsatisfactory proficiency scores. D6019 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(iv) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(iv) Ensure that an approved

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access