University Health Service

CLIA Laboratory Citation Details

4
Total Citations
24
Total Deficiencyies
13
Unique D-Tags
CMS Certification Number 23D0036143
Address 207 Fletcher Street, Ann Arbor, MI, 48109
City Ann Arbor
State MI
Zip Code48109
Phone(734) 764-8320

Citation History (4 surveys)

Survey - July 2, 2024

Survey Type: Standard

Survey Event ID: Y9W411

Deficiency Tags: D5400 D5417 D5439 D5445 D5461 D6053 D5209 D5400 D5417 D5439 D5445 D5461 D6053

Summary:

Summary Statement of Deficiencies D5209 PERSONNEL COMPETENCY ASSESSMENT POLICIES CFR(s): 493.1235 As specified in the personnel requirements in subpart M, the laboratory must establish and follow written policies and procedures to assess employee and, if applicable, consultant competency. This STANDARD is not met as evidenced by: . Based on record review and interview with the Laboratory Manager, the laboratory failed to follow its testing personnel competency assessment policies for 1 (Testing Personnel #5) of 35 testing personnel listed on Form CMS-209. Findings include: 1. A review of the laboratory's personnel competency records revealed Testing Personnel #5 was employed as a testing personnel starting on 1/10/23. One competency assessment was completed in April 2023. 2. A review of the laboratory's "Competency Assessment" policy revealed a section stating, "Annually, each technologist is observed by another qualified tech for each test performed at UHS. The observer watches the technologist perform the test. If the observer sees that every step is followed correctly, they will sign-off on the Direct Observation sheet with the date, their initials and the order number if applicable." 3. An interview on 7/1/24 at 10: 24 am with the Laboratory Manager confirmed the annual competency assessment for Testing Personnel #5 was not completed in accordance with laboratory policy. D5400 ANALYTIC SYSTEMS CFR(s): 493.1250 Each laboratory that performs nonwaived testing must meet the applicable analytic systems requirements in 493.1251 through 493.1283, unless HHS approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub.7), that provides equivalent quality testing. The laboratory must monitor and evaluate the overall quality of the analytic systems and correct identified problems as specified in Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 5 -- 493.1289 for each specialty and subspecialty of testing performed. This CONDITION is not met as evidenced by: . Based on observation, record review, and interviews, the laboratory failed to ensure Potassium Hydroxide (KOH) used to perform KOH preparations was not used when it had exceeded its expiration date (refer to D5417), failed to perform and document calibration verification every six months on the Tosoh AIA for human chorionic gonadotropin and ferritin (refer to D5439), failed to perform controls each date of patient testing fof Shiga toxin and Campylobacter patient testing dates (refer to D5445), and failed to perform and document quality control after changing reagents prior to resuming patient hematology testing using the Sysmex XN-550 (refer to D5461). D5417 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(d) Reagents, solutions, culture media, control materials, calibration materials, and other supplies must not be used when they have exceeded their expiration date, have deteriorated, or are of substandard quality. This STANDARD is not met as evidenced by: . Based on observation and interview with the Laboratory Manager, the laboratory failed to ensure Potassium Hydroxide (KOH) used to perform KOH preparations was not used when it had exceeded its expiration date for one bottle observed. Findings include: 1. The surveyor observed a bottle of EDM3 Potassium Hydroxide 10% with the expiration date of 4/22/24 near the microscope in the Treatment Center Clinic laboratory area on 7/1/24 at 9:07 am. 2. An interview on 7/1/24 at 9:07 am with the Laboratory Manager confirmed the laboratory performs KOH preparation testing and the bottle observed had exceeded it's expiration date. D5439 CALIBRATION AND CALIBRATION VERIFICATION CFR(s): 493.1255(b) Unless otherwise specified in this subpart, for each applicable test system the laboratory must do the following: Perform and document calibration verification procedure - (b)(1) Following the manufacturer's calibration verification instructions; (b)(2) Using the criteria verified or established by the laboratory under 493.1253(b)(3) -- (b)(2)(i) Including the number, type, and concentration of the materials, as well as acceptable limits for calibration verification; and (b)(2)(ii) Including at least a minimal (or zero) value, a mid-point value, and a maximum value near the upper limit of the range to verify the laboratory's reportable range of test results for the test system; and (b)(3) At least once every 6 months and whenever any of the following occur: (b)(3)(i) A complete change of reagents for a procedure is introduced, unless the laboratory can demonstrate that changing reagent lot numbers does not affect the range used to report patient test results, and control values are not adversely affected by reagent lot number changes. (b)(3)(ii) There is major preventive maintenance or replacement of critical parts that may influence test performance. (b)(3)(iii) Control materials reflect an unusual trend or shift, or are outside of the laboratory's acceptable limits, and other means of assessing and correcting unacceptable control values fail to identify and correct the problem. (b)(3)(iv) The laboratory's established schedule for verifying the reportable range for patient test results requires more frequent -- 2 of 5 -- calibration verification. This STANDARD is not met as evidenced by: . Based on record review and interview with Testing Personnel 3 (TP3), the laboratory failed to perform and document calibration verification every six months on the Tosoh AIA for human chorionic gonadotropin and ferritin for two (July 2022 to July 2024) of two years reviewed. Findings include: 1. Record review revealed that the laboratory did not perform calibration verification at least every six months from July 2022 to July 2024 for human chorionic gonadotropin and ferritin testing performed using the Tosoh AIA chemistry analyzer. 3. An interview with TP3 on 07/01/2024 at 3:30 pm confirmed calibration verification was not performed for ferritin and human chorionic gonadotropin at least every six months. D5445 CONTROL PROCEDURES CFR(s): 493.1256(d)(1)(2)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- (d)(1) Perform control procedures as defined in this section unless otherwise specified in the additional specialty and subspecialty requirements at 493.1261 through 493.1278. (d)(2) For each test system, perform control procedures using the number and frequency specified by the manufacturer or established by the laboratory when they meet or exceed the requirements in paragraph (d)(3) of this section. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: . Based on record review and interview with Laboratory Manager, the laboratory failed to perform controls each date of patient testing for 186 Shiga toxin patient testing dates and 179 for Campylobacter patient testing dates between July 2022 and July 2024. Findings include: 1. A review of the laboratory's "ImmunoCard STAT! EHEC Rapid test for Shiga toxins 1 and 2 in human stool" manufacturer's instructions revealed a section titled "Quality Control" stating, "This test should be performed per applicable local, state, or federal regulations or accrediting agencies" and "External control reagents should be tested according to the requirements of the laboratory or those of applicable local, state or accrediting agencies." 2. A review of the laboratory's "Campylobacter Quik Chek" manufacturer's instructions revealed a section titled "Quality Control" stating, "The reactivity of the CAMPYLOBACTER QUIK CHEK kit should be verified upon receipt using the Positive Control and negative ocntrol (Diluent). The Positive Control is supplied with the kit (gray-capped bottle). The Positive control confirms the reactivity of the other reagents associated with the assay, and is not intended to ensure precision at the analytical assay cut-off. Diluent is used for the negative control. Additional tests can be performed with the controls to meet the requirements of local, state, and/or federal regulations and/or accrediting organizations." 3. A review of the laboratory's "Microbiology Reagents- Quality Control Logsheets" from July 2022 to July 2024 revealed quality control testing was completed only monthly and with each new lot. 4. A review of patient testing records revealed a total of 186 patient testing dates between July 2022 and July 2024 when Shiga toxin quality control was not performed and 179 patient testing dates when Campylobacter quality control was not performed. 3. An interview with the -- 3 of 5 -- Laboratory Manager on 07/01/2024 at 10:41 am confirmed controls were not performed each day of testing for either Shiga toxin or Campylobacter and there was not an Individualized Quality Control Program (IQCP) in place. D5461 CONTROL PROCEDURES CFR(s): 493.1256(d)(6)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- Perform control material testing as specified in this paragraph before resuming patient testing when a complete change of reagents is introduced; major preventive maintenance is performed; or any critical part that may influence test performance is replaced. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: . Based on record review and interviews, the laboratory failed to perform and document quality control after changing reagents prior to resuming patient hematology testing using the Sysmex XN-550 eight times from 05/10/2023 to 06/27 /2024. Findings include: 1. A review of the laboratory's "Changing Reagents on the Sysmex XN-550" procedure revealed a lack of control procedure for ensuring reagents changed throughout the testing day were acceptable prior to use in patient testing. 2. An interview with TP1 on 07/01/2024 at 11:35 am revealed that reagents are replaced as needed, either upon expiration or when depleted on the instrument, which alerts the technician in both cases accordingly. TP1 indicated that quality control is not performed after change of reagents. 3. After reviewing Sysmex XN-550 onboard reagent inventory log, it was determined controls were not run after replacement of eight reagents: a. 5 Cellpack DCL reagents, lot number Y4007 (05/10 /2024, 05/21/2024, 06/03/2024, 06/13/2024) and lot number Y4014 (06/26/2024). b. 1 Cellpack DFL reagent, lot number A3040 (06/27/2024). c. 1 Flurocell WDF, lot number A3112 (05/30/2024). d. 1 Sulfolyser, lot number A3015 (06/20/2024). 4. A review of the laboratory's "Sysmex Automated Hematology Analyzer XN-550 Basic Operation" manufacturer's instructions revealed a section titled "When QC analysis is performed" stating, "QC is performed at the following times. Before sample analysis, after replacement/replenishment of reagents, after instrument maintenance, and when there is a concern about the accuracy of analysis values." 5. An interview with the LM on 07/01/2024 at 2:20 pm revealed quality controls had not been performed after change of reagents. D6053 TECHNICAL CONSULTANT RESPONSIBILITIES CFR(s): 493.1413(b)(9) The technical consultant is responsible for evaluating and documenting the performance of individuals responsible for moderate complexity testing at least semiannually during the first year the individual tests patient specimens. This STANDARD is not met as evidenced by: . Based on record review and interview with the Laboratory Manager, the Technical Consultant failed to evaluate the competency of testing personnel at least semiannually in the first year for 3 (Testing Personnel 8, 29, and 32) of 35 testing personnel listed on Form CMS-209. Findings include: 1. A review of the laboratory's testing personnel competency records revealed a lack of semiannual competency -- 4 of 5 -- assessment documentation for personnel that were new since the previous survey: a. Testing Personnel #8 had training and initial competency completed on 4/12/23 and a subsequent competency assessment completed on 5/22/24. b. Testing Personnel #29 had training and initial competency completed on 5/19/22 and a subsequent competency assessment completed on 6/6/23. c. Testing Personnel #32 had training and initial competency completed on 3/27/23 and no other competency assessments performed to date. 2. A review of the laboratory's "Competency Assessment" policy revealed a section stating, "Training checklists are utilized and new employees are allowed to work the bench independently after the training technologist completes the checklist. The new employee is evaluated again 6 months after the initial training." 3. A review of the laboratory's "PPM Competency Assessment" policy revealed a lack of process for semiannual competency assessment performance. 4. An interview on 7/1 /24 at (blank) with the Laboratory Manager confirmed the Technical Consultant had not performed and documented semiannual competency assessments with the testing personnel listed above. -- 5 of 5 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - June 6, 2022

Survey Type: Standard

Survey Event ID: ZCIG11

Deficiency Tags: D5473 D6047 D5473 D6047

Summary:

Summary Statement of Deficiencies D5473 CONTROL PROCEDURES CFR(s): 493.1256(e)(2)(g) (e) For reagent, media, and supply checks, the laboratory must do the following: (e) (2) Each day of use (unless otherwise specified in this subpart), test staining materials for intended reactivity to ensure predictable staining characteristics. Control materials for both positive and negative reactivity must be included, as appropriate. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: . Based on record review and interview with General Supervisor #1 (GS1), the laboratory failed to test staining materials for intended reactivity each day of use for peripheral blood smear testing for 2 (June 2020 to June 2022) of 2 years. Findings include: 1. A review of patient test records revealed patient 101294855 had a peripheral blood smear evaluated on 11/16/21. 2. The surveyor requested documentation of the staining characteristics assessments from June 2020 to June 2022 on 6/6/22 at 11:21 am and it was not made available. 3. A review of the laboratory's "PROCEDURE: 3.8 SLIDE SCANS (MANUAL SLIDE REVIEW) AND MANUAL DIFFERENTIAL COUNTS" revealed a lack of a process to document staining characteristics each day of use. 4. An interview on 6/6/22 at 11:23 am with GS1 revealed the laboratory did not establish a process for testing and documenting staining materials to ensure predictable staining characteristics. D6047 TECHNICAL CONSULTANT RESPONSIBILITIES CFR(s): 493.1413(b(8)(i) The procedures for evaluation of the competency of the staff must include, but are not limited to direct observations of routine patient test performance, including patient preparation, if applicable, specimen handling, processing and testing. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- This STANDARD is not met as evidenced by: . Based on record review and interview with the General Supervisor #1 (GS1), the Technical Consultant failed to assure personnel performing wet mount and potassium hydroxide (KOH) maintained their competency with the performance of direct observation of testing for 4 (Testing Personnel (TP) #25, #26, #27, and #28) of 28 testing personnel listed on the CMS-209 form. Findings include: 1. A review of the laboratory's competency assessments revealed a lack of documentation for TP #25, #26, #27, and #28 for the direct observation of testing for 2022. 2. An interview on 6 /06/2022 at 9:53 am, the GS1 confirmed the direct observation for the testing personnel listed above was not included in the 2022 assessment. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - December 14, 2020

Survey Type: Standard

Survey Event ID: 0VOH11

Deficiency Tags: D1000 D5411 D6046 D1000 D5411 D6046

Summary:

Summary Statement of Deficiencies D1000 CERTIFICATE OF WAIVER TESTS CFR(s): 493.15(c) Certificate of waiver tests. A laboratory may qualify for a certificate of waiver under section 353 of the PHS Act if it restricts the tests that it performs to one or more of the following tests or examinations (or additional tests added to this list as provided under paragraph (d) of this section) and no others: (1) Dipstick or Tablet Reagent Urinalysis (non-automated) for the following: (i) Bilirubin; (ii) Glucose; (iii) Hemoglobin; (iv) Ketone; (v) Leukocytes; (vi) Nitrite; (vii) pH; (viii) Protein; (ix) Specific gravity; and (x) Urobilinogen. (2) Fecal occult blood; (3) Ovulation tests-visual color comparison tests for human luteinizing hormone; (4) Urine pregnancy tests - visual color comparison tests; (5) Erythrocyte sedimentation rate-non-automated; (6) Hemoglobin- copper sulfate-non-automated; (7) Blood glucose by glucose monitoring devices cleared by the FDA specifically for home use; (8) Spun microhematocrit; and (9) Hemoglobin by single analyte instruments with self-contained or component features to perform specimen/reagent interaction, providing direct measurement and readout. This STANDARD is not met as evidenced by: . Based on record review and interview with the General Supervisor, the laboratory failed to ensure all authorized Fact Sheets were included with patient test result reports as required by the manufacturer for 1 (November 2020 to December 2020) of 1 month the laboratory has been testing COVID-19 specimens. Findings include: 1. A review of the laboratory's "Xpert Xpress SARS-CoV-2/Flu/RSV" package insert revealed a section stating, "Authorized laboratories using your product will include with test result reports, all authorized Fact Sheets." 2. An interview on 12/14/20 at 1: 15 pm with the General Supervisor revealed the laboratory did not distribute the authorized fact sheets with patient test result reports. D5411 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(a) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- Test systems must be selected by the laboratory. The testing must be performed following the manufacturer's instructions and in a manner that provides test results within the laboratory's stated performance specifications for each test system as determined under 493.1253. This STANDARD is not met as evidenced by: . Based on record review and interview with the General Supervisor, the point-of-care (POC) laboratories failed to implement, monitor, and document the room temperature and humidity readings for 2 (December 2018 to December 2020) of 2 years reviewed. Findings include: 1. During a tour of the four POC laboratories on 12/14/2020 at 9:36 AM, the surveyor noted the use of the following microscopes in the four laboratories: a. Treatment Center - Olympus CX 21 (room temperature 5 degrees to 40 degrees C (41 degree to 104 degree F); maximum relative humidity - 80%) b. Medical Center - Nikon Eclipse E200 (room temperature -0 to 40 degree C; maximum relative humidity 85%) c. Quick Clinic - Olympus CX 21 (room temperature 5 degrees to 40 degrees C (41 degree to 104 degree F); maximum relative humidity - 80%)) d. Gynecological and Sexual Health - 2 Olympus CX 21 and a AO One-Ten (Olympus - room temperature 5 degrees to 40 degrees C (41 degree to 104 degree F); maximum relative humidity - 80%) 2. A record review for 2 (December 2018 to December 2020) of 2 years revealed a lack of documentation to show the POC laboratories had implemented, monitored, and documented the room temperature and humidity readings for the proper operation of the microscopes in use. 3. An interview on 12/14 /2020 at 9:40 AM, the General Supervisor confirmed the POC laboratories had not implemented the monitoring and documenting of the room temperature and humidity readings. D6046 TECHNICAL CONSULTANT RESPONSIBILITIES CFR(s): 493.1413(b)(8) (b) The technical consultant is responsible for-- (b)(8) Evaluating the competency of all testing personnel and assuring that the staff maintain their competency to perform test procedures and report test results promptly, accurately and proficiently. This STANDARD is not met as evidenced by: . Based on record review and interview with the General Supervisor, the Technical Consultant failed to assure personnel performing Potassium Hydroxide (KOH) and Wet Mount Preparations maintained their competency for 20 (Testing Personnel #1, 2, 3, 4, 5, 7, 8, 9, 10, 11, 13, 19, 20, 21, 22, 23, 24, 25, 26, and 27) of 27 testing personnel listed on the CMS-209 form. Findings include: 1. A review of the laboratory's competency assessments revealed the following testing personnel did not have documented competency assessments performed in 2019: a. Testing Personnel #1 b. Testing Personnel #2 c. Testing Personnel #3 d. Testing Personnel #4 e. Testing Personnel #5 f. Testing Personnel #7 g. Testing Personnel #8 h. Testing Personnel #9 i. Testing Personnel #10 j. Testing Personnel #11 k. Testing Personnel #19 l. Testing Personnel #20 m. Testing Personnel #21 n. Testing Personnel #22 o. Testing Personnel #23 p. Testing Personnel #24 q. Testing Personnel #25 r. Testing Personnel #26 s. Testing Personnel #27 2. A review of the laboratory's "PPM Competency Assessment" policy revealed a section stating, "Direct observations of routine patient test performance, including patient preparation, if applicable, specimen handling, processing and testing. Annually, a designated observer will observe each PPM -- 2 of 3 -- provider perform testing. KOH and Wet Preps are the PPM testing done in UHS clinics. All steps of the procedures are observed and evaluated. Evaluation is recorded on the Provider Performed Microscopy Competency Checklist. 3. An interview on 12 /14/20 at 10:17 am with the General Supervisor confirmed competency assessments had not been performed for the testing personnel listed above. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - March 21, 2018

Survey Type: Standard

Survey Event ID: Z3U211

Deficiency Tags: D3031

Summary:

Summary Statement of Deficiencies D3031 RETENTION REQUIREMENTS CFR(s): 493.1105(a)(3) Analytic systems records. Retain quality control and patient test records (including instrument printouts, if applicable) and records documenting all analytic systems activities specified in 493.1252 through 493.1289 for at least 2 years. This STANDARD is not met as evidenced by: . Based on record review and interview, the laboratory failed to retain the endocrinology quality control documents for one of 25 patient charts reviewed for two years. Findings include: 1. On March 21, 2018 at 10:49 a.m., record review of the quality control for the endocrinology estradiol, lutenizing hormone, and prolaction testing revealed the laboratory did not have any documentation to show the quality control was run on the day of testing for one (#5) of 25 patient charts audited in April 2016 to present date. 2. On March 21, 2018 at 10:49 a.m. when queried, testing personnel # 1 as listed on the CMS-209 was not able to provide the surveyor the requested quality control documents. 3. During the interview on March 21, 2018 at 10: 49 a.m., testing personnel #1 confirmed the quality control data was not available to the surveyor for that day of endocrinology testing. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --