Urology Group Of Florida Llc

CLIA Laboratory Citation Details

2
Total Citations
9
Total Deficiencyies
7
Unique D-Tags
CMS Certification Number 10D1091566
Address 3399 Pga Blvd, Ste 230, Palm Beach Gardens, FL, 33410
City Palm Beach Gardens
State FL
Zip Code33410
Phone561 833-5594
Lab DirectorMURRAY GOLDBERG

Citation History (2 surveys)

Survey - December 9, 2024

Survey Type: Standard

Survey Event ID: 6ZBG11

Deficiency Tags: D0000 D5209 D5413

Summary:

Summary Statement of Deficiencies D0000 A recertification survey was conducted on 11/21/2024 to 12/09/2024. Urology Group of Florida LLC clinical laboratory was not in compliance with 42 CFR 493, requirements for clinical laboratories. D5209 PERSONNEL COMPETENCY ASSESSMENT POLICIES CFR(s): 493.1235 As specified in the personnel requirements in subpart M, the laboratory must establish and follow written policies and procedures to assess employee and, if applicable, consultant competency. This STANDARD is not met as evidenced by: Based on record review and interview, the laboratory failed to create a policy on when and who to perform competency assessments on. The laboratory failed to perform annual competency on 1 of 5 TP (testing personnel) (TP#E) in 2022 and 2023. Finding Include: Review of Laboratory Personnel Report revealed TP#E was a testing person for moderate complexity. The review of Policy and Procedure signed by the laboratory director on 5/31/2024 revealed no documentation of a policy on how and when initial, six months and annual competency assessments would be performed. Review of Personnel Competency Attestation revealed TP#E had no annual competency assessments in 2022 and/or 2023. Review of Patient Reports revealed TP#E performed urinalysis microscopy testing on 11/4/2024 and 12/7/2023 On 11/21 /2024 at 2:31 PM, the clinical manager confirmed TP#E did not have competency assessments performed in 2022 and 2023. D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: Based on observation, record review and interview, the laboratory failed to store blood specimen tubes at -20 Celsius(C) or colder past 24 hours for prostate-specific antigen (PSA) and testosterone (Testo) testing. Findings Included: On 11/21/2024 at 11:40 AM, a lab tour revealed blood tubes were stored in freezer #2 to be tested at a later date. Review of Patient Reports revealed: 1. PT#1 specimen was collected on 7 /19/2023 and reported 7/21/2023 for PSA testing. 2. PT#2 specimen was collected on 7 /19/2023 and reported 7/21/2023 for PSA testing. 3. PT#3 specimen was collected on 9 /11/2024 and reported 9/12/2024 for PSA testing. 4. PT#4 specimen was collected on 9 /11/2024 and reported 9/12/2024 for Testo testing. 5. PT#5 specimen was collected on 9/11/2024 and reported 9/12/2024 for Testo testing. Review of the PSA reagent package insert read, "serum samples is to be assayed within 24 hours after collection, the specimen should be stored in refrigerator at 2 to 8C. Specimens held for longer times (up to 5 months) should be frozen at -20C or colder." Review of Temperature policy read," Freezer temperature changes in January 2024 from -20 to -27 to -0 to -20." Review of Temperature Logs revealed from January 2024 to November 2024 temperature logs were recording temperatures of -0 to -20C. On 11/21/2024 at 1:30 PM, testing personnel stated they store blood tubes in freezer #2 for two days for PSA and Testo testing. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - November 17, 2022

Survey Type: Standard

Survey Event ID: 8WM411

Deficiency Tags: D0000 D5217 D5415 D5791 D5413 D5437

Summary:

Summary Statement of Deficiencies D0000 A recertification survey conducted from 11/08/2022 to 11/17/2022 found the UROLOGY GROUP OF FLORIDA, LLC clinical laboratory not in compliance with 42 CFR Part 493, Requirements for Laboratories. D5217 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(1) At least twice annually, the laboratory must verify the accuracy of any test or procedure it performs that is not included in subpart I of this part. This STANDARD is not met as evidenced by: Based on lack of records and laboratory director (LD) interview, the laboratory failed to verify the accuracy of testing method at least twice annually for SARS-2 CoV immunoglobulin G (IgG) antibodies since 2021. Findings include: -Review of Clinical Laboratory Improvement Amendments (CLIA) Application For Certification CMS- 116 form, revealed that the laboratory use the ACCESS SARS-CoV IgG test from Beckman Coulter for the detection of SARS-2 CoV IgG antibodies and the total estimated annual test volume of 848 tests. Records review revealed that the laboratory started testing since 02/01/2021. -The laboratory had no records of twice a year accuracy verification for the test of reference since they started testing. During an interview on 11/08/2022 at 2:10 PM with LD, he confirmed that the laboratory failed to perform at least twice a year accuracy verification for the SARS-2 CoV IgG test. D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: Based on user manual review and interview with testing personnel (TP) A, the laboratory failed to document room humidity requirement to assure optimal operation of the Access 2 immunoassay system analyzer for 2 out 2 years reviewed. Findings include: Review of Beckman Coulter Access 2 user manual revealed an operating environment requirement of humidity of 20 to 85 %. No documentation of the room humidity found for 2021 and 2022. During an interview on 11/08/2022 at 11:30 AM, TP A confirmed that there was no record of room humidity control check for the room where the instrument was located. D5415 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(c) Reagents, solutions, culture media, control materials, calibration materials, and other supplies, as appropriate, must be labeled to indicate the following: (1) Identity and when significant, titer, strength or concentration. (2) Storage requirements. (3) Preparation and expiration dates. (4) Other pertinent information required for proper use. This STANDARD is not met as evidenced by: Based on observation and staff interview, the laboratory failed to label Biorad Liquichek Immunoassay Plus Control level 1 and 3 in use with open date and the new expiration date at the time of the survey. Findings include: - During the laboratory tour on 11/08/2022 at 10:30 AM, the surveyor observed that the laboratory had in use 2 Liquichek Immunoassay Plus Control vials: one for level 1 and one for level 3 with Lot # 85300. The controls in use failed to have the opening date and the new expiration date. -Review of the Biorad insert, revealed that in Section "STORAGE AND STABILITY" stated on "Thawed Opened: Once thawed, opened and stored tightly capped at 2 to 8 C, this product will be stable as follows: -All analytes: 14 days." During an interview on 11/08/2022 at 11:35 AM, the Testing Personnel # A, confirmed that controls in use were not labeled as described above. D5437 CALIBRATION AND CALIBRATION VERIFICATION CFR(s): 493.1255(a) Unless otherwise specified in this subpart, for each applicable test system the laboratory must perform and document calibration procedures-- (1) Following the manufacturer's test system instructions, using calibration materials provided or specified, and with at least the frequency recommended by the manufacturer; (2) Using the criteria verified or established by the laboratory as specified in 493.1253(b) (3)-- (2)(i) Using calibration materials appropriate for the test system and, if possible, traceable to a reference method or reference material of known value; and (2)(ii) Including the number, type, and concentration of calibration materials, as well as acceptable limits for and the frequency of calibration; and (3) Whenever calibration verification fails to meet the laboratory's acceptable limits for calibration verification. -- 2 of 3 -- This STANDARD is not met as evidenced by: Based on record review and interview, the laboratory failed to follow manufacturer's instructions to perform calibration to the Access SARS Cov-2 IgG assay with a 28 day frequency as defined by the manufacturer for six out of eight months reviewed in 2022. Findings include: Review of the insert for the Access SARS CoV-2 IgG assay revealed that a calibration is required every 28 days. -Review of calibration records revealed that the laboratory performed calibration in 2022 as follows: 01/17/2022 to 02 /07/2022: 21 days. 02/07/2022 to 03/07/2022: 28 days. 03/07/2022 to 04/07/2022: 31 days. 04/07/2022 to 05/09/2022: 32 days. 05/09/2022 to 06/09/2022: 31 days. 06/09 /2022 to 07/18/2022: 42 days. 07/18/2022 to 08/18/2022: 31 days. 08/18/2022 to 10/13 /2022: 56 days. During an interview on 11/08/2022 at 01:25 PM, Testing Personnel # A, confirmed that the calibrations were performed in the days listed above and not following the frequency required by the manufacturer for 6 out of 8 months. D5791 ANALYTIC SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1289(a)(c) (a) The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess, and when indicated, correct problems identified in the analytic systems specified in 493.1251 through 493.1283. (c) The laboratory must document all analytic systems assessment activities. This STANDARD is not met as evidenced by: Based on record review and interview, the Quality Assessment (QA) failed to identify and correct that the freezer temperature for the storage of Biorad Liquichek Immunoassay Plus Control levels 1 and 3 was out of the acceptable range for 425 out of 458 days reviewed. The QA failed to have

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access