Us Dermatology Partners

CLIA Laboratory Citation Details

2
Total Citations
12
Total Deficiencyies
5
Unique D-Tags
CMS Certification Number 45D2103015
Address 1515 Medical Parkway Building 1, Suite 100, Cedar Park, TX, 78613
City Cedar Park
State TX
Zip Code78613
Phone(512) 260-5860

Citation History (2 surveys)

Survey - May 20, 2022

Survey Type: Standard

Survey Event ID: NFFB11

Deficiency Tags: D0000 D5217 D5601 D5891 D0000 D5217 D5601 D5891

Summary:

Summary Statement of Deficiencies D0000 The facility was found to be in compliance with applicable Conditions of Participation in the CLIA program, and recertification is recommended. D5217 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(1) At least twice annually, the laboratory must verify the accuracy of any test or procedure it performs that is not included in subpart I of this part. This STANDARD is not met as evidenced by: Based on review of Mohs accuracy peer reviews and interview, the laboratory failed to access accuracy of its Mohs testing of clear margins on the final stage and accurate maps for 2 of 2 years reviewed. Findings follow. A. Review of the Twice Annual Quality Assurance performed on 12/08/2021, 05/18/2021, 12/04/2020, and 06/16 /2020 showed the peer reviews were performed for "Final diagnosis". B. Interview with the histotech on May 20, 2022 at 1100 confirmed the diagnosis comes off the biopsy and agreed Mohs checks for clear margins on the final stage and should have accurate maps. D5601 HISTOPATHOLOGY CFR(s): 493.1273(a)(f) (a) As specified in 493.1256(e)(3), fluorescent and immunohistochemical stains must be checked for positive and negative reactivity each time of use. For all other differential or special stains, a control slide of known reactivity must be stained with each patient slide or group of patient slides. Reactions of the control slide with each special stain must be documented. (f) The laboratory must document all control procedures performed, as specified in this section. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- This STANDARD is not met as evidenced by: Based on review of the manufacturer's instructions, quality control records, patient charts, and interview, the laboratory failed to document the reactions of the immunohistochemical (IHC) stain control slides for two of two years reviewed. Findings follow. A. Review of the Novodiax ihcDirect SOX10 Ab-Enh Instructions for Use, IFU-00036-EN-A July 2020, under Quality Control Procedures stated, "Positive and negative controls should be run simultaneously with patient specimens. Positive Tissue Control: The recommended positive control tissues for this antibody are properly processed melanoma and skin. The staining is nuclear for melanoma cells and melanocytes in skin. One positive tissue control for each set of test conditions should be included in each staining run. Previous tissue specimens that have been frozen and freshly cut or in some cases, an individual's own tissue may be used as controls... Negative Tissue Control: The same tissue used for the positive control may be used as the negative tissue control." B. Review of the laboratory's quality control records from 2022- 2020 showed no documentation of the ICH stains. C. Review of 11 patient test reports, slides, and maps showed 4 included the ihc stain SOX10. Review of the patient charts for the 2022 cases: 0277, 0273, 0254, 0186 did not mention the performance of the controls. D. Interview with the histotech on May 20, 2022 at 1340 confirmed the quality control for SOX10 was not noted in the patient's chart. D5891 POSTANALYTIC SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1299(a) The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess and, when indicated, correct problems identified in the postanalytic systems specified in 493.1291. This STANDARD is not met as evidenced by: Based on review of the testing logs, patient charts, and interview, the laboratory failed to ensure testing for KOH and Scabies was recorded on the appropriate testing logs for two of two months reviewed for four of four patients. Findings follow. A. Review of the Scabies Logs showed results for 4 patients (3 negative, 1 positive) from 09/01 /2021 - 10/12/2021. B. Review of the corresponding patient charts showed all were reported as a KOH: three negatives for hyphae, and one positive for spores. No mention of Scabies test performed. MRN 1076754, 09/01/2021, postitive: spores; MRN 5380045, 09/28/2021, negative: no hyphae; MRN 5203648, 10/08/2021, negative: no hyphae; MRN 2674649, 10/12/2021, negative: no hyphae. C. Interview with the Lead Medical Assistant on May 20, 2022 at 1415 acknowledged the medical assistants logged the testing for the physician, and the Scabies Log must have been used to document the KOH testing. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - December 11, 2020

Survey Type: Standard

Survey Event ID: 7ZQE11

Deficiency Tags: D0000 D3011 D0000 D3011

Summary:

Summary Statement of Deficiencies D0000 The laboratory was surveyed and found to be in substantial compliance with the conditions of the CLIA regulations found at CFR 42 493.1 through 493.1780 and recertification is recommended. D3011 FACILITIES CFR(s): 493.1101(d) Safety procedures must be established, accessible, and observed to ensure protection from physical, chemical, biochemical, and electrical hazards, and biohazardous materials. This STANDARD is not met as evidenced by: Based on surveyor observations, review of facility procedures and records, and interview with facility staff, the laboratory failed to ensure the emergency eye wash saline was not expired for 6 of 6 months reviewed. The findings included: 1. At 13:54 hours on 12/11/2020, the surveyor observed the emergency eye wash saline, lot number 13049-21, had expired on 01/2016. 2. Based on review of laboratory policy last approved by the laboratory director on 12/03/2020, the policy titled "Quality Control Policies and Documentation" stated "The following equipment must be monitored" and included "Eye Wash: Must be tested each day for proper working order." 3. Based on review of the form titled "2020 Eye Wash Log", the eye wash station was checked 8 times in June 2020, 11 times in July 2020, 17 times in August 2020, 17 times in September 2020, 15 times in October 2020, 14 times in November 2020, and 7 times between December 1, 2020 and the say of the inspection, December 11, 2020, for a total of 89 documented checks in 6 of 6 months reviewed. 4. In an interview on 12/11/2020 at 14:00 hours in the laboratory, the histotech stated she was unaware the emergency eyewash saline had an expiration date. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access