Utah Podiatry Group

CLIA Laboratory Citation Details

2
Total Citations
6
Total Deficiencyies
3
Unique D-Tags
CMS Certification Number 46D2162903
Address 24 S 1100 E, Suite 210, Salt Lake City, UT, 84102
City Salt Lake City
State UT
Zip Code84102
Phone(801) 505-5277

Citation History (2 surveys)

Survey - August 24, 2021

Survey Type: Standard

Survey Event ID: T2DM11

Deficiency Tags: D5435 D5435

Summary:

Summary Statement of Deficiencies D5435 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(b)(2) For equipment, instruments, or test systems developed in-house, commercially available and modified by the laboratory, or maintenance and function check protocols are not provided by the manufacturer, the laboratory must: (i) Define a function check protocol that ensures equipment, instrument, and test system performance that is necessary for accurate and reliable test results and test result reporting. (ii) Perform and document the function checks, including background or baseline checks, specified in paragraph (b)(2)(i) of this section. Function checks must be within the laboratory's established limits before patient testing is conducted. This STANDARD is not met as evidenced by: Based on observation and interview with the technical supervisor, pipette calibration was not performed annually per protocol. Findings include: 1. Calibration stickers on Thermo Scientific 1-10 uL, 10-100 uL, and 100-1000 uL single channel pipettes indicated calibration was due on 7/23/21. 2. In an interview on 8/24/21 at approximately 10:30 am, the technical supervisor confirmed that pipettes were overdue for annual calibration. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - August 27, 2019

Survey Type: Standard

Survey Event ID: 8QEF11

Deficiency Tags: D5423 D5449 D5423 D5449

Summary:

Summary Statement of Deficiencies D5423 ESTABLISHMENT AND VERIFICATION OF PERFORMANCE CFR(s): 493.1253(b)(2) Each laboratory that modifies an FDA-cleared or approved test system, or introduces a test system not subject to FDA clearance or approval (including methods developed in-house and standardized methods such as text book procedures), or uses a test system in which performance specifications are not provided by the manufacturer must, before reporting patient test results, establish for each test system the performance specifications for the following performance characteristics, as applicable: (2)(i) Accuracy. (2)(ii) Precision. (2)(iii) Analytical sensitivity. (2)(iv) Analytical specificity to include interfering substances. (2)(v) Reportable range of test results for the test system. (2)(vi) Reference intervals (normal values). (2)(vii) Any other performance characteristic required for test performance. This STANDARD is not met as evidenced by: Based on nail fungus assay validation record review and interview with staff, the laboratory failed to include validation samples of the same matrix as the patient samples tested to verify analytical specificity for 22 of 22 fungal organisms included in their nail fungus panel. The laboratory began patient testing in 03/2019 and had tested approximately 100 samples. Findings include: 1. Laboratory validation records failed to include documentation the laboratory had performed studies using the same sample matrix (nail samples in COPAN E Swab transport media) in verification studies to assure nail samples did not include interfering substances that might affect test results. 2. In an interview with the technical consultant at approximately 1:00 PM, the consultant confirmed that testing had been performed with target organisms in transport media, but did not include testing using the same sample types that were tested in the laboratory (nail clippings). D5449 CONTROL PROCEDURES CFR(s): 493.1256(d)(3)(ii)(g) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- At least once a day patient specimens are assayed or examined perform the following for-- Each qualitative procedure, include a negative and positive control material; (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on patient test records review, quality control record review, lack of documentation, and interview with staff, the laboratory failed to include a positive control each day of testing for 22 of 22 fungal targets included in their nail fungus test panel. That laboratory began testing in 03/2019 and had tested approximately 100 samples. Findings include: 1. Quality control records reviewed for 3 dates patient samples were tested (03/17/2019, 04/10/2019, and 04/17/2019) lacked documentation of a positive control for each of the 22 fungal organisms included in the panel. 2. The laboratory lacked documentation of a Individualized Quality Control Plan (IQCP) demonstrating they could perform quality control at a reduced frequency (less than each day of testing) that would provide equivalent quality testing. 3. The laboratory technical supervisor stated during interview on 08/27/2019 at approximately 1:00 PM, the laboratory used Bacillus Atrophaeus as an extraction control, but failed to include a positive control for each fungal target each day of testing -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access