Virginia Cardiovascular Specialists Heart

CLIA Laboratory Citation Details

2
Total Citations
12
Total Deficiencyies
5
Unique D-Tags
CMS Certification Number 49D2265914
Address 8007 Discovery Dr, Richmond, VA, 23229
City Richmond
State VA
Zip Code23229
Phone(804) 323-5011

Citation History (2 surveys)

Survey - October 16, 2025

Survey Type: Standard

Survey Event ID: R70Z11

Deficiency Tags: D0000 D5209 D5291 D5807 D0000 D5209 D5291 D5807

Summary:

Summary Statement of Deficiencies D0000 An announced CLIA recertification survey was conducted at Virginia Cardiovascular Specialists on October 16, 2025 by the Virginia Department of Health's Office of Licensure and Certification. The laboratory was surveyed under 42 CFR part 493 CLIA Regulations. Virginia Cardiovascular Specialists was not in compliance with the applicable Conditions and Standards under 42 CFR part 493 CLIA Regulations. Specific deficiencies are as follows: D5209 PERSONNEL COMPETENCY ASSESSMENT POLICIES CFR(s): 493.1235 As specified in the personnel requirements in subpart M, the laboratory must establish and follow written policies and procedures to assess employee and, if applicable, consultant competency. This STANDARD is not met as evidenced by: Based on a review of the Centers for Medicare and Medicaid Services Laboratory Personnel Report form (CMS 209), personnel records, lack of documentation and interview, the laboratory failed to establish and follow a policy for one (1) of 1 Technical Consultant (TC) competency assessment from April 2024 through the date of the survey, 10/16/25. The findings include: 1. Review of the CMS 209 revealed the laboratory director (LD) identified one Technical Consultant (TC) for the specialties of Hematology and Chemistry, TC #1. (See attached personnel code sheet.) 2. Review of the laboratory's personnel records from April 2024 through 10/16/25 revealed no competency assessment documented for TC #1. The surveyor requested to review the competency assessment of duties performed as a technical consultant. The TC stated at approximately 10 AM on 10/16/25 that there was no documentation available for review. 3. Review of the laboratory policy and procedure manual revealed the lack of a policy outlining the performance and documentation of TC competency assessment. 4. In an exit interview with the TC on October 16, 2025 at 11:25 AM, the above findings were confirmed. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- D5291 GENERAL LABORATORY SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1239(a) The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess, and, when indicated, correct problems identified in the general laboratory systems requirements specified at 493.1231 through 493.1236. This STANDARD is not met as evidenced by: Based on a review of the proficiency testing (PT) records, laboratory policy and procedure manual, lack of documentation, and interviews, the laboratory failed to establish a written policy to test, submit, and assess results of proficiency samples at the time of the survey on 10/16/25. The findings include: 1. Review of the laboratory's PT records revealed the laboratory participates in American Pathology Institute (API) proficiency testing as customer number 85063 for the Chemistry Core and Hematology modules. 2. Review of the laboratory's policy and procedure manual revealed the lack of a written policy for testing proficiency samples, submitting PT results to API, and assessing returned results. When asked on 10/16/25 at 11:15 AM if the lab had a PT policy, the technical consultant (TC) stated that there was none. 3. In an exit interview with the TC on 10/16/25 at 11:45 AM, the findings were confirmed. D5807 TEST REPORT CFR(s): 493.1291(d) (d) Pertinent "reference intervals" or "normal" values, as determined by the laboratory performing the tests, must be available to the authorized person who ordered the tests and, if applicable, the individual responsible for using the test results. This STANDARD is not met as evidenced by: Based on a review of the laboratory's survey Clinical Laboratory Improvement Amendments (CLIA) Application for Certification form (CMS 116), Abbott i-STAT patient result reports, lack of documentation and interviews, the laboratory's Activated Clotting Time (ACT) and Chemistry (Chem 8+) patient reports failed to include reference intervals for twenty one (21) of 21 patient test reports reviewed. The findings include: 1. Pre-survey review of the submitted CMS 116 revealed the laboratory utilizes the Abbott i-STAT with Chem 8+(analytes: Sodium, potassium, chloride, Ionized calcium, total Carbon dioxide, glucose, blood urea nitrogen (BUN), creatinine, hemoglobin, hematorcrit) and ACT cartridges for patient testing. 2. Review of the patient logs from September 2025 through the date of the survey, 10/16/25, revealed individual patient worksheets that contained a patient label along with the corresponding i-STAT result print out. Twenty one (21) of 21 Chem 8+ and ACT patient reports reviewed lacked reference intervals for the above listed tests. When asked about reference range availability at 10:41 AM on 10/16/25, the Technical Consultant (TC) stated that the ranges were not in the Electronic Medical Record (EMR). 3. In an exit interview with the TC on October 16, 2025 at 11:25 AM, the findings were confirmed. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - March 13, 2024

Survey Type: Standard

Survey Event ID: 8TOW11

Deficiency Tags: D0000 D5447 D0000 D5447

Summary:

Summary Statement of Deficiencies D0000 An announced CLIA Initial survey was conducted at the Virginia Cardiovascular Specialists Heart and Vascular Center on 03/13/24 by the Virginia Department of Health's Office of Licensure and Certification. The laboratory was surveyed under 42 CFR part 493 CLIA Requirements. Specific deficiencies cited are as follows: D5447 CONTROL PROCEDURES CFR(s): 493.1256(d)(3)(i)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- At least once a day patient specimens are assayed or examined perform the following for-- Each quantitative procedure, include two control materials of different concentrations; (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on the review of the laboratory's initial verification and Individualized Quality Control Plan (IQCP) documentation, quality control (QC) records, daily patient test logs, lack of documentation, and an interview, the laboratory failed to perform at least two levels of QC materials each day of patient testing for the non-waived Abbott i- STAT Celite Activated Clotting Time (ACT) analyte/cartridge for six of six days reviewed from 01/09/24 through 02/27/24 and reporting a total of 8 patients. Findings include: 1. Review of the laboratory's initial verification documentation the for the i- STAT Celite ACT analyte/cartridge revealed an IQCP policy reviewed and approved by the laboratory director on 02/28/24. 2. Review QC records and daily patient testing logs revealed a lack of documentation of at least two levels of QC materials assayed for the following dates (prior to the IQCP approval by the laboratory director): 01/09 /24- 2 patients reported, 01/16/24- 1 patient reported, 02/12/24- 1 patient reported, 02 /13/24- 2 patient reported, 02/21/24- 1 patient reported and 02/27/24- 1 patient reported. 3. An exit interview with the technical consultant on 03/13/24 at 10:45 AM confirmed the findings. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access