Virginia Pediatric & Adolescent Center Pc

CLIA Laboratory Citation Details

1
Total Citation
4
Total Deficiencyies
2
Unique D-Tags
CMS Certification Number 49D0942551
Address 4001 Fair Ridge Dr #301, Fairfax, VA, 22033
City Fairfax
State VA
Zip Code22033
Phone703 569-8400
Lab DirectorKIA HARKLESS

Citation History (1 survey)

Survey - March 18, 2025

Survey Type: Standard

Survey Event ID: ZGVH11

Deficiency Tags: D0000 D5439 D0000 D5439

Summary:

Summary Statement of Deficiencies D0000 An announced CLIA recertification survey was conducted at Virginia Pediatric & Adolescent Medicine on March 18, 2025 by the Virginia Department of Health's Office of Licensure and Certification. The laboratory was surveyed under 42 CFR part 493 CLIA Regulations. The specific deficiency cited is as follows: D5439 CALIBRATION AND CALIBRATION VERIFICATION CFR(s): 493.1255(b) (b)(1) Following the manufacturer's calibration verification instructions; (b)(2) Using the criteria verified or established by the laboratory under 493.1253(b)(3)-- (b)(2)(i) Including the number, type, and concentration of the materials, as well as acceptable limits for calibration verification; and (b)(2)(ii) Including at least a minimal (or zero) value, a mid-point value, and a maximum value near the upper limit of the range to verify the laboratory's reportable range of test results for the test system; and (b)(3) At least once every 6 months and whenever any of the following occur: (b)(3)(i) A complete change of reagents for a procedure is introduced, unless the laboratory can demonstrate that changing reagent lot numbers does not affect the range used to report patient test results, and control values are not adversely affected by reagent lot number changes. (b)(3)(ii) There is major preventive maintenance or replacement of critical parts that may influence test performance. (b)(3)(iii) Control materials reflect an unusual trend or shift, or are outside of the laboratory's acceptable limits, and other means of assessing and correcting unacceptable control values fail to identify and correct the problem. (b)(3)(iv) The laboratory's established schedule for verifying the reportable range for patient test results requires more frequent calibration verification. This STANDARD is not met as evidenced by: Based on a laboratory tour, review of the laboratory's policies and procedures, Reichert UNISTAT Bilirubinometer calibration verification records, lack of documentation and interviews, the laboratory failed to establish and follow a policy to perform calibration verification for the Reichert Unistat Bilirubinometer every 6 Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- months during the twenty-four (24) months reviewed from January 2023 until January 2025. The findings include: 1. During a tour of the laboratory on March 18, 2025, at 9: 00 AM, the surveyor noted a Reichert Unistat Bilirubinometer analyzer in use for Neonatal Bilirubin patient testing. 2. Review of the laboratory's policies and procedures revealed a lack of a policy for the every 6 month performance of calibration verification of the Reichert Unistat Bilirubinometer. 3. Review of the laboratory's Reichert Unistat Bilirubinometer calibration verification records from January 2023 until January 2025 revealed calibration verification was performed on 01 /06/2023, 08/10/2023, 12/22/2023, 06/25/2024 and 12/18/2024. The surveyor requested to review Neonatal Bilirubin calibration verification documentation performed in the timeframe of July 2023. The laboratory provided no further documentation for review. 4. In an exit interview with the technical consultant at 12: 00 PM on March 18, 2025, the findings were confirmed. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access