Wakemed Urology

CLIA Laboratory Citation Details

2
Total Citations
12
Total Deficiencyies
8
Unique D-Tags
CMS Certification Number 34D2089691
Address 210 Ashville Ave, Cary, NC, 27518
City Cary
State NC
Zip Code27518
Phone919 350-7180
Lab DirectorCARMIN KALORIN

Citation History (2 surveys)

Survey - May 6, 2025

Survey Type: Standard

Survey Event ID: KM0G11

Deficiency Tags: D5781 D6063 D6065

Summary:

Summary Statement of Deficiencies D5781

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - July 14, 2021

Survey Type: Standard

Survey Event ID: UJPO11

Deficiency Tags: D5447 D6013 D6020 D6021 D6021 D5421 D5447 D6013 D6020

Summary:

Summary Statement of Deficiencies D5421 ESTABLISHMENT AND VERIFICATION OF PERFORMANCE CFR(s): 493.1253(b)(1) Each laboratory that introduces an unmodified, FDA-cleared or approved test system must do the following before reporting patient test results: (1)(i) Demonstrate that it can obtain performance specifications comparable to those established by the manufacturer for the following performance characteristics: (1)(i)(A) Accuracy. (1)(i) (B) Precision. (1)(i)(C) Reportable range of test results for the test system. (1)(ii) Verify that the manufacturer's reference intervals (normal values) are appropriate for the laboratory's patient population. This STANDARD is not met as evidenced by: Based on absence of performance specification records for the Abbott I-STAT CHEM8+ cartridges and interview with the Manager of Clinical Quality and Education 7/14/21, the laboratory failed to verify the performance specifications of the Abbott I-STAT CHEM8+ cartridges when it was determined by the FDA to be moderate complexity. Approximately 97 patients were affected. Findings: On January 14, 2020 Abbott Point of Care released a customer letter (APOC2020-001) stating the Abbott I-STAT CHEM8+ cartridge was not Federal Drug Administration (FDA) cleared or approved for use. On 2/19/20 the Abbott I-STAT Chem 8+ cartridge was cleared by the FDA and categorized as moderate complexity. Review of laboratory records revealed no documentation the laboratory had verified the performance specifications of the Abbott I-STAT CHEM8+ cartridge before continuing to perform patient testing. Review of laboratory testing records, sent via email after survey date, revealed approximately 97 patients were tested from 2/19/20 until 8/19/20 when the laboratory ceased testing on the I-STAT and began testing on the Piccolo analyzer. Interview with Manager of Clinical Quality and Education at approximately 9:45 a.m. confirmed the laboratory failed to verify the performance specifications of the Abbott Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- I-STAT CHEM8+ cartridge. She stated the facility had been notified by Abbott in regards to the Chem 8+ cartridges, but they continued to use them until they could get a new test system, the Piccolo, validated and in place. D5447 CONTROL PROCEDURES CFR(s): 493.1256(d)(3)(i)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- At least once a day patient specimens are assayed or examined perform the following for-- Each quantitative procedure, include two control materials of different concentrations; (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on review of laboratory quality control (QC) records for the I-STAT CHEM8+ cartridge, review of laboratory testing records and interview with the Manager of Clinical Quality and Education 7/14/21, the laboratory failed to perform QC on the Abbott I-STAT CHEM8+ cartridge each day of patient testing for 6 months, from 2/19 /20 until 8/19/20. Approximately 97 patients were affected. Findings: On January 14, 2020 Abbott Point of Care released a customer letter (APOC2020-001) stating the Abbott I-STAT CHEM8+ cartridge was not FDA cleared or approved for use. On 2/19 /20 the Abbott I-STAT Chem 8+ cartridge was cleared by the FDA and categorized as moderate complexity. Review of laboratory QC records revealed the laboratory was performing QC for the Abbott I-STAT CHEM8+ cartridge with each new lot number or shipment and at least every 30 days. The laboratory failed to perform QC each day of patient testing. The laboratory performed QC on 2/28/20, 3/9/20, 5/5/20, 5/27/20 and 6/24/20. Review of laboratory testing records, sent via email after survey date, revealed approximately 97 patients were tested from 2/19/20 until 8/19/20 when the laboratory ceased testing on the I-STAT and began testing on the Piccolo analyzer. Interview with Manager of Clinical Quality and Education at approximately 9:45 a.m. confirmed the laboratory was not performing QC each day of patient testing. She stated the facility had been notified by Abbott in regards to the Chem 8+ cartridges, but they continued to use them until they could get a new test system, the Piccolo, validated and in place. D6013 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(3)(ii) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(3) Ensure that-- (e)(3)(ii) Verification procedures used are adequate to determine the accuracy, precision, and other pertinent performance characteristics of the method; This STANDARD is not met as evidenced by: Based on deficiency cited 7/14/21, the laboratory director (LD) failed to ensure performance verifications were performed on the Abbott I-STAT CHEM8+ cartridges. Findings: See D5421. -- 2 of 3 -- D6020 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(5) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(5) Ensure that the quality control program is established and maintained to assure the quality of laboratory services provided. This STANDARD is not met as evidenced by: Based on deficiency cited 7/14/21, the LD failed to ensure QC was performed as required on the Abbott I-STAT CHEM8+ cartridge. Findings: See D5447. D6021 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(5) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(5) Ensure that quality assessment programs are established and maintained to assure the quality of laboratory services provided. This STANDARD is not met as evidenced by: Based on review of laboratory quality assessment records, review of

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access