Wave Medical Group Inc

CLIA Laboratory Citation Details

2
Total Citations
7
Total Deficiencyies
7
Unique D-Tags
CMS Certification Number 05D2258471
Address 720 Paularino Ave, Ste 102, Costa Mesa, CA, 92626
City Costa Mesa
State CA
Zip Code92626
Phone(949) 288-0624

Citation History (2 surveys)

Survey - November 21, 2025

Survey Type: Special

Survey Event ID: BNWV11

Deficiency Tags: D2016 D6000 D0000 D2096 D6016

Summary:

Summary Statement of Deficiencies D0000 A proficiency testing desk review survey waas performed on 11/21/2025, the laboratory was found not in compliance with the following CONDITION LEVEL DEFICIENCIES D2016 - 42 C.F.R. 493.803 Condition: Successful (proficiency testing) participation; and D6000 - 42 C.F.R. 493.1403 Condition: Laboratories performing moderate complexity testing; laboratory director. D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on review of the Certification and Survey Provider Enhanced Reporting (CASPER) - 0155D and American Proficiency Institute (API) records (2025-2, and 2025-3), the laboratory failed to successfully participate in a proficiency testing Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- program approved by HHS for each specialty, subspecialty and analyte or test in which the laboratory is certified under CLIA, the laboratory failed to successfully participate in the analyte Uric Acid - resulting in unsuccessful performance. See D2096. D2096 ROUTINE CHEMISTRY CFR(s): 493.841(f) (f) Failure to achieve satisfactory performance for the same analyte or test in two consecutive testing events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on review of the Certification and Survey Provider Enhanced Reporting (CASPER) Report 0155D Individual Laboratory Profile and American Proficiency Institute (API) report, the laboratory failed to achieve satisfactory performance for two of three consecutive events (2025-2 and 2025-3) for the analyte Uric Acid. The finding include: Uric Acid 20% - 2025 second testing event; Uric Acid 40% - 2025 third testing event; A review of the 2025 scores from American Proficiency Institute (API) confirmed the above findings. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on a proficiency testing desk review of the CASPER 0155D report and American Proficiency Institute records for 2025-2 and 2025-3 events, the laboratory director failed to provide overall management and direction of the laboratory services. Refer to D6016. D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) (e)(4)(i) The proficiency testing samples are tested as required under Subpart H of this part; This STANDARD is not met as evidenced by: Based on a proficiency testing desk review of the CASPER 0155D report and American Proficiency Institute records for 2025-2 and 2025-3 events, the laboratory director failed to ensure successful participation in an HHS proficiency testing program. Refer to D2096. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - August 16, 2024

Survey Type: Standard

Survey Event ID: FHIB11

Deficiency Tags: D6007 D5415

Summary:

Summary Statement of Deficiencies D5415 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(c) Reagents, solutions, culture media, control materials, calibration materials, and other supplies, as appropriate, must be labeled to indicate the following: (1) Identity and when significant, titer, strength or concentration. (2) Storage requirements. (3) Preparation and expiration dates. (4) Other pertinent information required for proper use. This STANDARD is not met as evidenced by: Based on the surveyor's observation during the laboratory's tour and interviews with the technical consultant (TC) and testing personnel (TP), it was determined that the laboratory failed to label various reagents used for test performance to indicate the reagent's opening, preparation, and expiration dates when such materials are used in the laboratory. The findings include: 1. Based on the surveyor's observation during the laboratory tour on August 16, 2024, at approximately 1:10 pm, no opening, preparation, or open stability expiration date labels were used or documented for all test reagents used for the Routine Chemistry and Endocrinology subspecialties. For example, TPO Ab conjugate, Substrate reagent II, B12 Pre-treatment, Vitamin D Pre- treatment, TPO Ab/Tg Ab sample diluent, etc. 2. The TP affirmed by interview on August 16, 2024, at approximately 1:10 p.m. that the reagents used in the laboratory as mentioned in statement #1 were not labeled with the opening, preparation, and expiration dates or documented in a reagent preparation log. 3. Based on the laboratory's annual testing declaration submitted at the time of the survey, the laboratory analyzed approximately 7,960 Routine Chemistry and Endocrinology patients' specimens for which testing materials were not labeled. D6007 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(1) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (E) The laboratory director must-- (E)(1) Ensure that testing systems developed and used for each of the tests performed in the laboratory provide quality laboratory services for all aspects of test performance, which includes the preanalytic, analytic, and postanalytic phases of testing; This STANDARD is not met as evidenced by: Based on the deficient practice cited, the laboratory director is herein cited for deficient practice in overall administration of the laboratory to ensure that reagents are labeled with expiration and opening date as indicated by the manufacturer is established. See D5415 -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access