Wellstar Sylvan Grove Hospital

CLIA Laboratory Citation Details

3
Total Citations
10
Total Deficiencyies
7
Unique D-Tags
CMS Certification Number 11D1010218
Address 1050 Mcdonough Road, Jackson, GA, 30233
City Jackson
State GA
Zip Code30233
Phone(770) 775-7861

Citation History (3 surveys)

Survey - January 30, 2019

Survey Type: Standard

Survey Event ID: GPZO11

Deficiency Tags: D0000 D3009

Summary:

Summary Statement of Deficiencies D0000 A Clinical Laboratory Improvement Amendments (CLIA) recertification survey was completed on January 30, 2019. The laboratory was not in compliance with applicable CLIA requirements found at 42 CFR 493.1 through 42 CFR 493.1780. The following deficiency was cited: D3009 FACILITIES CFR(s): 493.1101(c) The laboratory must be in compliance with applicable Federal, State, and local laboratory requirements. This STANDARD is not met as evidenced by: Review of the Laboratory Director (LD) qualification documents, and staff interview, the LD did not meet the state requirements for the position of Laboratory Director. Findings: 1. Review of the LD qualification documents, the current LD did not have a current Georgia License, which is required to fill the LD position for a High Complexity Laboratory. 2. Interview with staff # 1 and #2 (CMS 209 form), on January 30, 2019 at approximately 1 pm, in the Hospital Conference Room, confirmed that the current LD did not have a current Georgia License. He had previously let his Georgia License expire. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - May 22, 2018

Survey Type: Special

Survey Event ID: M8CX11

Deficiency Tags: D0000 D2016 D2130

Summary:

Summary Statement of Deficiencies D0000 A proficiency testing desk review was completed on May 22, 2018. At the time of the review, the laboratory was not in compliance with the Clinical Laboratory Improvement Amendments of 1988, 42 CFR 493.1 through 42 CFR 493.1780. The following deficiencies were cited: D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on proficiency testing desk review using the Centers for Medicare and Medicaid (CMS) Casper Reports 155 and 153 and confirmation from the laboratory manager, the laboratory failed to maintain satisfactory performance on samples provide by the College of American Pathologist (CAP) in two consecutive events (2nd Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- and 3rd events of 2017), resulting in the first unsuccessful occurrence for#760 the speciality of hematology and analyte # 795 hematocrit (HCT). Findings include: Refer to D 2130 D2130 HEMATOLOGY CFR(s): 493.851(f) Failure to achieve satisfactory performance for the same analyte in two consecutive events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on proficiency testing desk review using the Centers for Medicare and Medicaid (CMS) Casper Reports 155 and 153 and confirmation from the laboratory manager, the laboratory failed to maintain satisfactory performance on samples provide by the College of American Pathologist (CAP) in two consecutive events (2nd and 3rd events of 2017), resulting in the first unsuccessful occurrence for#760 the speciality of hematology and analyte # 795 hematocrit (HCT). Findings include: 1. Desk review of Casper Reports 153 and 155 disclosed the laboratory failed the subspecialty of Hematology analyte # 760 on events 2 and 3 of 20017 with scores of 50 % and failed analyte #785 HCT on events 2 and 3 of 2017 with scores of 0%. 2. Verbal and email correspondence with the laboratory manager on March 08, 2018 confirmed the laboratory failed Hematology and HCT on PT samples provided by CAP on Events 2 and 3 of 2017 resulting in the first unsuccessful performance on Hematology samples provided by CAP. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - May 21, 2018

Survey Type: Special

Survey Event ID: I01X11

Deficiency Tags: D0000 D2016 D2096 D6000 D6016

Summary:

Summary Statement of Deficiencies D0000 A proficiency testing desk review was completed on May 21, 2018. At the time of the review, the laboratory was not in compliance with the Clinical Laboratory Improvement Amendments of 1988, 42 CFR 493.1 through 42 CFR 493.1780. The following deficiencies were cited: D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on proficiency testing desk review using the Centers for Medicare and Medicaid (CMS) Casper Reports 155 and 153 and confirmation from the laboratory manager, the laboratory failed to maintain satisfactory performance on samples provide by the College of American Pathologist (CAP) in three consecutive events Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- (2nd and 3rd events of 2017 and 1st event of 2018), resulting in the second unsuccessful occurrence for Routine Chemistry, analyte # 245 including Creatinine, analyte # 405 and Blood Urea Nitrogen (BUN), analyte # 505. Findings include: Refer to D 2096 D2096 ROUTINE CHEMISTRY CFR(s): 493.841(f) Failure to achieve satisfactory performance for the same analyte or test in two consecutive testing events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on proficiency testing (PT) desk review using the Centers for Medicare and Medicaid (CMS) Casper Reports 155 and 153 and verbal and email confirmation from the laboratory manager, the laboratory failed to maintain satisfactory performance in three consecutive events (2nd and 3rd events of 2017 and 1st event of 2018), resulting in the second unsuccessful occurrence for Routine Chemistry, analyte number 245 including Creatinine, analyte # 405 and Blood Urea Nitrogen (BUN), analyte # 505. Findings include: 1. Desk review of Casper Reports 153 and 155 disclosed the laboratory failed the subspecialty of # 245 Routine Chemistry including analyte #405, Creatinine and # 505 BUN on events 2 and 3 of 2017 with a score of 0% and event 1 of 2018 with a score of 0%. 2. Verbal and email correspondence with the laboratory manager on March 08, 2018 confirmed the laboratory failed Routine Chemistry, Creatinine and BUN on PT samples provided by the College of American Pathologist (CAP) on Events 2 and 3 of 2017 and Event 1 of 2018 resulting in the second unsuccessful performance. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on proficiency testing desk review using the Centers for Medicare and Medicaid (CMS) Casper Reports 155 and 153 and confirmation from the laboratory manager, the laboratory director failed to ensure the laboratory maintained satisfactory performance on samples provide by the College of American Pathologist (CAP) in three consecutive events (2nd and 3rd events of 2017 and 1st event of 2018), resulting in the second unsuccessful occurrence for Routine Chemistry, analyte # 245 including Creatinine, analyte # 405 and Blood Urea Nitrogen (BUN), analyte # 505. Findings include: refer to D 6016 . D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently -- 2 of 3 -- and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(i) Ensure that the proficiency testing samples are tested as required under Subpart H of this part; This STANDARD is not met as evidenced by: Based on proficiency testing desk review using the Centers for Medicare and Medicaid (CMS) Casper Reports 155 and 153 and confirmation from the laboratory manager, the laboratory director failed to ensure the laboratory maintained satisfactory performance on samples provide by the College of American Pathologist (CAP) in three consecutive events (2nd and 3rd events of 2017 and 1st event of 2018), resulting in the second unsuccessful occurrence for Routine Chemistry, analyte # 245 including Creatinine, analyte # 405 and Blood Urea Nitrogen (BUN), analyte # 505. Findings include: 1. Desk review of Casper Reports 153 and 155 disclosed the laboratory failed the subspecialty of # 245 Routine Chemistry including analyte #405, Creatinine and # 505 BUN on events 2 and 3 of 2017 with a score of 0% and event 1 of 2018 with a score of 0%. 2. Verbal and email correspondence with the laboratory manager on March 08, 2018 confirmed the laboratory failed Routine Chemistry, Creatinine and BUN on PT samples provided by the College of American Pathologist (CAP) on Events 2 and 3 of 2017 and Event 1 of 2018 resulting in the second unsuccessful performance. Also refer to D 2096 -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access