Survey - June 3, 2019

Survey Type: Special

Survey Event ID: J6E411

Deficiency Tags: D0000 D2016 D2130 D6000 D6016

Summary:

Summary Statement of Deficiencies D0000 A proficiency testing desk review was completed on June 3, 2019. At the time of the review, the laboratory was not in compliance with the Clinical Laboratory Improvement Amendments of 1988, 42 CFR 493.1 through 42 CFR 493.1780. The following deficiencies were cited: D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on proficiency testing desk review using the Centers for Medicare and Medicaid (CMS) Casper Reports 155 and 153 and review of the laboratory's proficiency testing (PT) reports, the laboratory failed to maintain satisfactory performance in two consecutive events (3rd event of 2018 and 1st event of 2019), Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- resulting in the first unsuccessful occurrence for Hematology # 760. Findings include: Refer to D2130 D2130 HEMATOLOGY CFR(s): 493.851(f) Failure to achieve satisfactory performance for the same analyte in two consecutive events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on proficiency testing desk review using the Centers for Medicare and Medicaid (CMS) Casper Reports 155 and 153 and review of the laboratory's proficiency testing (PT) reports, the laboratory failed to maintain satisfactory performance in two consecutive events (3rd event of 2018 and 1st event of 2019), resulting in the first unsuccessful occurrence for Hematology # 760. The findings include: 1. Desk review of Casper Reports 153 and 155 disclosed the laboratory failed Hematology # 0760 on Event 3 of 2018 with a score of 0% and Event 1 of 2019 with a score of 0%. 2. The criteria for acceptable performance for the specialty of Hematology is a score of 80%. 2. Desk review of the laboratory's proficiency testing reports from the American Proficiency Institute (API) confirmed the laboratory failed Hematology on event 3 of 2018 and event 1 of 2019 resulting in the first unsuccessful performance. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on proficiency testing desk review using the Centers for Medicare and Medicaid (CMS) Casper Reports 155 and 153 and review of the laboratory's American Proficiency Institute (API) proficiency testing (PT) reports, the laboratory director failed to ensure the laboratory maintained satisfactory performance in two of three consecutive events (3rd event of 2018 and 1st event of 2019), resulting in the first unsuccessful occurrence for Hematology #760. The findings include: Refer to D6016 D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(i) Ensure that the proficiency testing samples are tested as required under Subpart H of this part; This STANDARD is not met as evidenced by: -- 2 of 3 -- Based on proficiency testing desk review using the Centers for Medicare and Medicaid (CMS) Casper Reports 155 and 153 and review of the laboratory's American Proficiency Institute (API) proficiency testing (PT) reports, the laboratory director failed to ensure the laboratory maintained satisfactory performance in two of three consecutive events (3rd event of 2018 and 1st event of 2019), resulting in the first unsuccessful occurrence for Hematology #760. The findings include: 1. Desk review of Casper Reports 153 and 155 disclosed the laboratory failed Hematology # 0760 on Event 3 of 2018 with a score of 0% and Event 1 of 2019 with a score of 0%. 2. Desk review of the laboratory's proficiency testing reports from the American Proficiency Institute (API) confirmed the laboratory failed Hematology on event 3 of 2018 and event 1 of 2019 resulting in the first unsuccessful performance. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - July 30, 2018

Survey Type: Standard

Survey Event ID: Y6Z411

Deficiency Tags: D0000 D2009 D5209 D5221 D5403 D5407 D6033 D6035 D6046

Summary:

Summary Statement of Deficiencies D0000 A Clinical Laboratory Improvement Amendments (CLIA) recertification survey was completed on July 30, 2018. The laboratory was not in compliance with applicable CLIA requirements found at 42 CFR 493.1 through 42 CFR 493.1780. The following deficiencies were cited: D2009 TESTING OF PROFICIENCY TESTING SAMPLES CFR(s): 493.801(b)(1) The individual testing or examining the samples and the laboratory director must attest to the routine integration of the samples into the patient workload using the laboratory's routine methods. This STANDARD is not met as evidenced by: Based on review of the American Proficiency Institute (API) proficiency testing (PT) records and interview with the laboratory coordinator , the laboratory director failed to attest that PT samples were tested in the same manner as patient specimens by failing to sign attestation forms for Hematology/ coagulation events #2 and #3 of 2017. Findings include: 1. Review of the American Proficiency Institute (API) PT records revealed the laboratory director failed to sign the attestation documents for the 2017 testing events #2 and #3. 2. An interview with the laboratory coordinator on 7/30/18 at approximately 01:30 PM in the review room, confirmed the attestations were not signed. D5209 PERSONNEL COMPETENCY ASSESSMENT POLICIES CFR(s): 493.1235 As specified in the personnel requirements in subpart M, the laboratory must establish and follow written policies and procedures to assess employee and, if applicable, consultant competency. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 5 -- This STANDARD is not met as evidenced by: A review of laboratory records and interview with the laboratory coordinator , it was determined that the laboratory failed to provide Competency Assessment for its testing personnel on Hematology testing. Findings include: 1. A review of testing personnel (TP) records revealed there was no annual competency evaluations for testing personnel (#3 - #6 CMS 209) for 2016, 2017 and 2018 on Hematology testing. 2. The laboratory also failed to have semi-annual competencies for testing personnel (#2 - #6 CMS 209). 3. An interview with the laboratory coordinator on July 17, 2018 at 01:36 PM in the review room confirmed that there was no current annual and semi- annual competencies performed for testing personnel. D5221 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(d) All proficiency testing evaluation and verification activities must be documented. This STANDARD is not met as evidenced by: Based on document review and interview with the laboratory coordinator, the laboratory failed to perform