Citation History (2 surveys)

Survey - September 17, 2026

Survey Type: Standard

Survey Event ID: 5OR711

Deficiency Tags: D5209 D5401 D6091 D6102

Summary:

Summary Statement of Deficiencies D5209 PERSONNEL COMPETENCY ASSESSMENT POLICIES CFR(s): 493.1235 As specified in the personnel requirements in subpart M, the laboratory must establish and follow written policies and procedures to assess employee and, if applicable, consultant competency. This STANDARD is not met as evidenced by: Based on review of laboratory's policy and procedure manuals, competency assessment records, a review of ten (10) Histopathology patient test records, and interviews on September 17, 2026, it was determined that one (1) of four (4) testing personnel (TP) who performed high complexity gross examination did not have competency assessment prior to testing patient. The findings included: 1. The laboratory conducted high-complexity histopathology tests, including both gross (macroscopic) and microscopic examinations. Four testing personnel (TP) were responsible for performing gross examinations. 2. On the day of the survey, the laboratory did not maintain records documenting competency training and assessment for TP #4. The TP #4 performed at least one gross examination of pericardial tissue on March 6, 2026. 3. On September 17, 2026, at approximately 1:30 p.m. laboratory compliance manager and general supervisor confirmed the laboratory failed to maintain competency assessment for TP#4. 4. The laboratory's testing declaration form, signed by the laboratory director on August 24, 2026, stated that the laboratory performed approximately 21,385 tests including gross examination annually. D5401 PROCEDURE MANUAL CFR(s): 493.1251(a) (a) A written procedures manual for all tests, assays, and examinations performed by the laboratory must be available to, and followed by, laboratory personnel. Textbooks may supplement but not replace the laboratory's written procedures for testing or Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- examining specimens. This STANDARD is not met as evidenced by: Based on review of laboratory's policy and procedure manuals, proficiency testing (PT) records, a review of ten (10) Histopathology patient test records, and interviews on September 17, 2026, it was determined that the laboratory did not follow the laboratory's policy and procedure for PT testing review in 2024, 2025 and 2026. The findings included: 1. The laboratory participated in the College of American Pathologists (CAP) Proficiency Testing (PT) Program for HER2 immunohistochemistry (HER2) and ER/PGR immunohistochemistry TMA. The testing included both microscopic and macroscopic examinations. The laboratory's PT procedure manual required the director to review and sign the final reports. 2. On the day of the survey, the surveyor reviewed randomly selected laboratory PT evaluation records. The histopathology testing evaluation reports for 2024, 2025, and 2026 had been reviewed and signed by the histologic technician supervisor. The laboratory maintained no documentation showing that the laboratory director or a delegated pathologist had reviewed the PT evaluation reports. 3. On September 17, 2026, at approximately 1:00 p.m. laboratory compliance manager and histologic technician supervisor confirmed the PT evaluation report did not sign by the laboratory director or delegated staff. 4. The laboratory's testing declaration form, signed by the laboratory director on August 24, 2026, stated that the laboratory performed approximately 21,385 tests including gross examination annually. D6091 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(4)(iii) (e)(4)(iii) All proficiency testing reports received are reviewed by the appropriate staff to evaluate the laboratorys performance and to identify any problems that require

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - June 29, 2022

Survey Type: Special

Survey Event ID: RMIO11

Deficiency Tags: D5407 D5619 D5637 D5641 D6103 D9999

Summary:

Summary Statement of Deficiencies D5407 PROCEDURE MANUAL CFR(s): 493.1251(d) Procedures and changes in procedures must be approved, signed, and dated by the current laboratory director before use. This STANDARD is not met as evidenced by: Based on review of 14 laboratory policies and procedures and interview, the laboratory failed to ensure that four of 14 written procedures were approved, signed and dated by the Laboratory Director. Findings include: 1. The Laboratory Director failed to sign and date four of 14 laboratory procedures. Procedures include: - QUALITY ASSURANCE PROGRAM FOR SURGICAL PATHOLOGY - ASSESSING PROFESSIONAL COMPETENCY - NON-GYN PAPANICOLAOU STAIN: MANUAL METHOD - PATHOLOGIST CYTOLOGY WORKLOAD MONITORING AND LIMITS 2. During an interview on June 29, 2022 at 10:00 AM, these findings were confirmed with the Practice Manager. D5619 CYTOLOGY CFR(s): 493.1274(b)(3) (b) Staining. The laboratory must have available and follow written policies and procedures for each of the following, if applicable: (b)(3) Nongynecologic specimens that have a high potential for cross-contamination must be stained separately from other nongynecologic specimens, and the stains must be filtered or changed following staining. This STANDARD is not met as evidenced by: Based on review of laboratory policies and procedures, lack of records and interview, the laboratory failed to establish written policies and procedures for identifying non- Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- gynecologic specimens with a high potential for cross-contamination and staining them separately from other non-gynecologic specimens and filtering or changing the stains following staining. Findings include: 1. The Survey Team requested and the laboratory failed to provide written policies and procedures for identifying non- gynecologic specimens with a high potential for cross-contamination and staining them separately from other non-gynecologic specimens and filtering or changing the stains following staining. 2. The Survey Team requested and the laboratory failed to provide documentation of cases with a high potential for cross-contamination which had been stained separately and the stains and reagents changed following staining in 2020, 2021 and to the date of survey in 2022. 3. During an interview on June 28, 2022 at 1:00 PM, these findings were confirmed with the Practice Manager. D5637 CYTOLOGY CFR(s): 493.1274(d)(1)(ii) (d) Workload limits. The laboratory must establish and follow written policies and procedures that ensure the following: (d)(1)(ii) Each individual's workload limit is reassessed at least every 6 months and adjusted when necessary. This STANDARD is not met as evidenced by: Based on review of laboratory policies and procedures, lack of records and interview, the laboratory failed to establish written policies and procedures to reassess and adjust, when necessary, a maximum workload limit at least every six months for the Technical Supervisors who performed primary screening of non-gynecologic cytology specimens. Findings include: 1. The Survey Team requested and the laboratory failed to provide written policies and procedures to detail how the Technical Supervisors' workload limits would be reassessed at least every six months and adjusted when necessary. 2. The Survey Team requested and the laboratory failed to provide records of a workload reassessment at least every six months for five of five Technical Supervisors in 2020, 2021 and to the date of the survey 2022. Technical Supervisors include: - Technical Supervisor #1 - Technical Supervisor #2 - Technical Supervisor #3 - Technical Supervisor #4 - Technical Supervisor #5 3. During an interview on June 28, 2022 at 1:30 PM, these findings were confirmed with the Practice Manager. D5641 CYTOLOGY CFR(s): 493.1274(d)(2)(ii) (d) Workload limits. The laboratory must establish and follow written policies and procedures that ensure the following: (d)(2)(ii) For the purposes of establishing workload limits for individuals examining slides in less than an 8-hour workday (includes full-time employees with duties other than slide examination and part-time employees), a period of 8 hours is used to prorate the number of slides that may be examined. The formula-- Number of hours examining slides X 100 / 8 is used to determine maximum slide volume to be examined; This STANDARD is not met as evidenced by: Based on review of laboratory policies and procedures, lack of records and interview, the laboratory failed to establish written policies and procedures to ensure that the workload limits for the Technical Supervisors would be prorated when examining cytology slides in less than an eight-hour work day. Findings include: 1. The Survey Team requested and the laboratory failed to provide written policies and procedures to -- 2 of 3 -- prorate the workload limits for the Technical Supervisors when examining non- gynecologic cytology slides in less than an eight-hour day. 2. The Survey Team requested and the laboratory failed to provide documentation of prorated workload limits for five of five Technical Supervisor when examining slides in less than an eight-hour work day. Technical Supervisors include: - Technical Supervisor #1 - Technical Supervisor #2 - Technical Supervisor #3 - Technical Supervisor #4 - Technical Supervisor #5 3. During an interview on June 28, 2022 at 1:30 PM, these findings were confirmed with the Practice Manager. D6103 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(13) The laboratory director must ensure that policies and procedures are established for monitoring individuals who conduct preanalytical, analytical, and postanalytical phases of testing to assure that they are competent and maintain their competency to process specimens, perform test procedures and report test results promptly and proficiently, and whenever necessary, identify needs for remedial training or continuing education to improve skills. This STANDARD is not met as evidenced by: Based on review of laboratory policies and procedures, lack of competency assessment records and interview, the Laboratory Director failed to establish written policies and procedures to assess the competency of the laboratory assistants performing preparation of cytology specimens. The Laboratory Director failed to assess the competency of two of two laboratory assistants in 2020, 2021 and to the date of the survey in 2022. Findings include: 1. The Survey Team requested and the Laboratory Director failed to provide written policies and procedures to describe the process for assessing the competency of the laboratory assistants. 2. The Survey Team requested and the Laboratory Director failed to provide documentation of competency assessments for two of two laboratory assistants who prepared cytology specimens in 2020, 2021 and to the date of the survey in 2022. 3. During an interview on June 28, 2022 at 9:50 AM, these findings were confirmed with the Practice Manager. D9999 By agreement between ASCT Services, Inc. and CMS, information provided for CMS's completion of CMS Form 670 are ASCT Services, Inc. averages only. This information is confidential and proprietary to ASCT Services, Inc., is exempt under the Freedom of Information Act (5 U.S.C. 552 et seq.), and shall be used for federal government purposes only. -- 3 of 3 --